Search results

  1. Wigum

    Unexpected boiler shut-down after yearly service

    To be fair, the guy could of recharged the vessel and the core could of started passing. Things like this happen and maybe im picking you up wrong but you seem to want to find someone to blame. Calm down. Far more important things to worry about
  2. Wigum

    Is this likely to be asbestos flue?

    Looks like a suprima he. Won't be asbestos.
  3. Wigum

    Honneywell to hive thermostat change

    A into 1 and b into 3
  4. Wigum

    Anyone recognise this gas fitting?

    I actually think your probably right. I thought looking at the picture there was a groove where the washer should be.
  5. Wigum

    Anyone recognise this gas fitting?

    They'll come out within 2 hours to confirm if its leaking or not. They may even have the washer. Its hardly a repair.
  6. Wigum

    Anyone recognise this gas fitting?

    Hi, thats a bonded washer for the pedestol iso valve. It is needed. Phone 0800 111 999. I would advise to get sorted asap
  7. Wigum

    Ideal classic ff250

    It could also be installed remotely from the boiler. How many tanks do you have in the loft? Do you have a red tank in the house anywhere?
  8. Wigum

    Baxi 105HE cutting out every 12-24hrs

    It should retract all the way back. I would take a guess that the water venturi beneath the diaphragm in partrially blocked. If it was fully blocked you would get no movement
  9. Wigum

    Does any body know what boiler this is and how do I wire a thermostat to it

    Just wire like I said and you wont have to worry about no voltage or not. The common comes from the boiler so you'll be fine. Just don't link live to common. Just make sure it's dead so you don't get a shock when wiring it up!
  10. Wigum

    Does any body know what boiler this is and how do I wire a thermostat to it

    When you flip the panel down there will be a cover with two screws, located at the bottom when looking straight down. You will then have a connection that you unplug. Wire one to the common on the thermostat and the other to calling.
  11. Wigum

    Ideal C24 HE Mini - no ignition

    My opinion is that he should of advised the guys to get someone who is qualified to do the job. Incorrectly fitting a flue could be fatal
  12. Wigum

    Ideal C24 HE Mini - no ignition

    I remember seeing the b and q "expert" advise a couple of guys on how to fit a flue turret who then went on to buy it. They were struggling to understand what he was saying as their English wasn't very good
  13. Wigum

    Replacement Combi Boiler

    Not had time to read all the posts, but have you considered considered asking your installer what he recommends? Thats what I'd advise
  14. Wigum

    Dripping water tank

    Last time I had this it was an old lead pipe leaking under the floor
  15. Wigum

    Dripping water tank

    I would be looking at a leak somewhere. If it was just passing I would expect the cwsc to over flow
  16. Wigum

    Advice please Worcester 24cdi hot water problems

    No problem. One warning though, sometimes you really have to be in front of the boiler to properly diagnose
  17. Wigum

    Advice please Worcester 24cdi hot water problems

    Look up how to gas rate your boiler. Do this when your running the hot tap and no other appliances running
  18. Wigum

    Advice please Worcester 24cdi hot water problems

    If the radiators are staying cold and the burner is staying lit try turning the flow rate down
  19. Wigum

    Advice please Worcester 24cdi hot water problems

    Does the hw light come on when the tap is on? Check to see if the radiators are getting hot when the tap is on? Could be something as simple as the flow rate is too fast.