Search results

  1. O

    Leak below boiler after PHE swap

    The issue with the increase in pressure when the heating is on will be related to the expansion vessel. It’s either burst, needs recharged or the connecting pipe or flex is choked with grit.
  2. O

    Central heating flow issue: Boiler lockout

    The boiler might have a pump over run built into the electronics. Is there a an automatic bypass on the external pipework to facilitate a pump over run? I had wee look at the instructions after reading Ian’s post and as he states,there’s only a fan over run. It does state in the instruction...
  3. O

    Replacement TRV Heads

    I very much doubt you’ll get replacement heads for those valves. I’m sure they are Danfoss. You could try their website but I think you’ll need to renew the valves too.
  4. O

    Combi or Conventional.

    Jeezo, Ian is correct, you do like to google. I don’t really need or want a history lesson in how combi boilers were developed. Those links aren’t even relevant to the statement you’ve highlighted. It’s not hot news that the government want to ban gas boilers from new builds and distric heating...
  5. O

    Combi or Conventional.

    Only you and the Mrs in the house plus you have a couple of electric showers. Combi all day long. Your hot water demand isn’t much is it unless youse both like to take a bath everyday. If your boiler was to break down, having an electric shower is a pretty good back up. You can always boil a...
  6. O

    Riello RDB1 - Lockout - Suspect Pump Clogged or Broken

    Take the burner out and have a look. If it hasn’t been serviced for years then maybe it’s clogged with soot. I wouldn’t guess it’s any particular part. Spend the money and get an expert in.
  7. O

    Valliant ecotec 837-losing pressure often-topping up almost daily now

    Disconnect the prv pipe at the bottom of the boiler if you can't find where it terminates. If it's loosing pressure here you'll soon know as this pipe should be dry inside. Disconnect it when the boilers off and cold.
  8. O

    Baxi main eco elite automatic air vent leaking *PIC*

    Hi AGAS. Don't apologise, your entitled to your opinion. I based my statement on my experience. Maybe they're more reliable these days as I never shut them anymore to save the hassle. I had to change a return isolator on a potterton promax that was weeping from the ball last week which would be...
  9. O

    wiring wifi switch into HW on LP522

    Hw on will be number 3 on the timer backplate, it will be number 7 on your diagram.
  10. O

    Baxi main eco elite automatic air vent leaking *PIC*

    Isolator valves on some filters and a lot of boilers are prone to leaking when closed/opened. You've landed lucky if they're not leaking after doing a repair.
  11. O

    Red light on Modena 80E

    Sorry, I'm just guessing. I wouldn't advise you to replace anything, as like I stated before it could be gas related, so you need to be qualified. A red light on that boiler would indicate a fault relating to failed ignition.
  12. O

    Earth fault with a boiler

    Maybe a water leak somewhere inside the boiler. Did the plumber chap take the casing off and have a look inside? Not all plumbers are good with finding faults inside boilers. Find a boiler break down engineer instead.
  13. O

    Red light on Modena 80E

    Your welcome. You did ask for any ideas! Do you have a multi meter or a set of test lamps? How did you come to the conclusion that the timer was the fault? Maybe it's the pump? Or perhaps the pcb? Or maybe even the water pressure switch? There's no point in throwing parts into the boiler...
  14. O

    Red light on Modena 80E

    Maybe better calling in an expert instead of trying to guess when you haven got a clue!