    bath panels

    Any decent plumber would know that to install a bath panel and an end panel you would need to build a frame around the bath after installation. Preferably 2"x2" wood is used. The panels are then fitted to this frame, screwed in at the bottom and the heads of the screws covered by caps. This...
  2. P

    Hot water from expansion pipe

    What is the height of the expansion pipe? i.e. Is it rasied well above the tank and then drops in the shape of a big U or does it only just go over the edge of the tank with the end just above the water line? If it's the latter, then this could be the cause of the recycling of water. You need to...
  3. P

    bath shower taps

    Close hot and cold taps tightly. Turn button anti-clockwise,it will screw off. depending on type of taps, there should be either a phillips screw or valve. Both of which are easily removed. the washer sits attatched.
  4. P

    Cold radiator upstairs...searched but did not find an answer

    You need to define make and model of boiler. Almost certain there is not enough pressure in the system, that's why you have no success with the upper floor radiator. Also need to state the position the boiler is located with regards to upper radiator. System should run on a pressure of 1.0 bar...
  5. P

    overheat switch trips

    No you do not have a blockage and a power flush would be a waste of time and money in this case. Almost certain the pump is not working to it's full capacity. I would have this checked out before doing anything. If problems persist then post back :D
  6. P

    No pressure in PowerMax boiler

    Could be any one of a few problems but start with filling the system up again to its regular pressure (1.0 to 1.5 bar) run the system. First check the pressure relief outlet (15mm copper pipe coming out of the wall running down to approx 6-8 inches off the ground) is not showing any signs of...
  7. P

    can anybody help?

    Not sure about hot water problem but had similar case last week. Due to the recent cold spell, after every test known to me i found a bad leak under the floor boards on ground floor. This was due to almost non-existant insulation, luckily there was enough space under floor boards to crawl around...