  1. T

    Worcester Heatslave 12/14 going into lockout

    Hi Guys, I have been meaning to write up the steps I went through for quite a while, time seems to have eluded me! I have run through all the tests suggested by the helpful forum members in this thread, checking and then replacing the photocell, setting up the electrodes etc. all with no...
  2. T

    Worcester Heatslave 12/14 going into lockout

    Snb New jet fitted and pump bled 3 times as the manual says. I have also checked and cleaned the cartridge filter in the pump. Tony
  3. T

    Worcester Heatslave 12/14 going into lockout

    Have fitted the new photocell this evening, still doing the same thing. Any ideas what to do next? Tony
  4. T

    Worcester Heatslave 12/14 going into lockout

    Karate kid, I have taken it out of the burner and cleaned it. No change. Have ordered a new photocell now, should arrive Tuesday, see how we get on. Thanks for your help. Tony
  5. T

    Worcester Heatslave 12/14 going into lockout

    I haven't tried that, didn't want to damage the control box. I have ordered a new photocell now, thanks for your help though. Tony
  6. T

    Worcester Heatslave 12/14 going into lockout

    Karate kid, No hot water from the boiler since April, washing up has been going in the dishwasher and we have a great electric shower. I will get a photocell ordered and give it a try. Thanks for your help. Tony
  7. T

    Worcester Heatslave 12/14 going into lockout

    Hello, I have a Worcester Heatslave 12/14 combi oil boiler which will not run. We ran out of oil back in April this year and due to the hot weather and finances have only just got round to getting the tank filled. On first starting the boiler it goes into lockout, to be expected with no oil...