  1. N

    Accenta 8 mini adding Second Bellbox/Siren

    Ok cool the size is the same so will order that one
  2. N

    Accenta 8 mini adding Second Bellbox/Siren

    Bit of a Update i opened up the Control unit and this is how currently how the wiring is wired up does it look right? I have not wired up the second bell box yet but thought I would take a look inside the panel. Another thing When i opened up the panel the backup battery is knackered , now the...
  3. N

    Accenta 8 mini adding Second Bellbox/Siren

    Hi So run same core cable from the Accenta Control unit ,( Double up) and run that to the rear house Siren?
  4. N

    Accenta 8 mini adding Second Bellbox/Siren

    Hi Ok So Do i put the Jumper on the front house siren into SCB and LC on the Siren Box PCB . Or Just on The Rear Siren box which i am going to fit. And then double up on the wires from the Accenta control unit to the rear house siren? Sorry new to this !
  5. N

    Accenta 8 mini adding Second Bellbox/Siren

    Hi All i have The Accenta 8 Mini Alarm System I currently have 1 Siren with Strobe Unit connected to front of the house and a internal Siren , I wanted to know if i can add another Siren at the back of the house Into the Accenta 8 mini control unit. I cannot see where i could connect up a second...
  6. N

    Baxi 105e Remote Expansion vessel adding.

    Depressurise the system by draining and gauge on 0 then I pumped vessel to around 0.8 bar .
  7. N

    Baxi 105e Remote Expansion vessel adding.

    Ok I will give it a go and see if it cures my problem, Yes I would try pumping your vessel up and see if it stays pressurised over a few days.
  8. N

    Baxi 105e Remote Expansion vessel adding.

    Hi so did yours have the same issue where the pin does not come out enough to push the micro switch , and this kit fixed that problem or your DV was leaking ? I have changed the lateral pin nut earlier in the year because mine was leaking but not the top nut which is the one which does not come...
  9. N

    Baxi 105e Remote Expansion vessel adding.

    Yes so far so good has not lost any pressure since pumping it up Only issue i do have is on the diverter valve the little pins which come out and push against the micro switch does not always come out meaning the boiler does not ignite Only the vertical one seems to play up .
  10. N

    Magnaclean micro or micro 2

    Hi all I want to fit one of these filters to my boiler as I currently do not have one Due to limited space on my return pipe I need to fit the micro filter Now there is two types a Magnaclean micro and micro 2 anybody know the differences?
  11. N

    Baxi 105e Remote Expansion vessel adding.

    Hi all I pumped up the original vessel over the weekend and so far so good has not lost pressure on gauge when CH has been on and off Another question the drain point on the right hand of my 2nd pic on the return pipe Is that where I would drain the radiators / sytem from I'm assuming this will...
  12. N

    Baxi 105e Remote Expansion vessel adding.

    Doing a bit of reading looks like some vessels can also be fitted on the flow side .
  13. N

    Baxi 105e Remote Expansion vessel adding.

    Hi so the filling loop pipe line which goes to the 22mm left side in pic this is not where you would connect a remote vessel as that is a feed into boiler? So I would connect it to the R/H 22mm that is the CH return right ?
  14. N

    Baxi 105e Remote Expansion vessel adding.

    Ok I can give that a go I was under the impression if it leaks out of the expansion valve the the vessel is shot if I still press it water is still trickling out slowly
  15. N

    Baxi 105e Remote Expansion vessel adding.

    # Update I managed to taking the panelling off around the boiler and gained access to the vessel valve I pressed it and some water came out with very little air and rest of the air seems to be expelled Can I just try topping it up or does water indicate vessels shot?
  16. N

    Baxi 105e Remote Expansion vessel adding.

    I have added another better pic of the under side if it helps.
  17. N

    Baxi 105e Remote Expansion vessel adding.

    Hi ok yes I will try and access the vessel problem I have is its all boxed in but will try and hava a go.
  18. N

    Baxi 105e Remote Expansion vessel adding.

    So looking at the small pipe which goes to the vessel it connects to the brass PRV and this pipe I have arrowed also comes off the PRV which is going to the filling loop.
  19. N

    Baxi 105e Remote Expansion vessel adding.

    Ok so I could simple disconnect the filling loop fit a t piece in between and run a pipe off the T piece to a remote vessel and that's it? I'm only assuming the vessel is shot due to symptoms I'm having with it Problem I have is access to the vessel and valve to repressurise
  20. N

    Baxi 105e Remote Expansion vessel adding.

    Hi thanks for your reply Sorry when you say R/H return is that the one with the lever on (filling loop)?