Search results

  1. D

    REALLY replace PCB? Vokera Comp.HE 25. Please help (cold Xmas ahead!!)

    "The cause would be firing the boiler before filling it completely with water" ...which is what I did 48 hours ago...sigh. So yes, pres button, reset. All well. (I'm replacing seals of box as I close it all up. And I have 2 CO-detectors mounted in the area - not that is is a substitute for...
  2. D

    REALLY replace PCB? Vokera Comp.HE 25. Please help (cold Xmas ahead!!)

    Vulcan Continental....I remember the name well; When I lived in the UK 20 years ago, the house that I had just bought actually had a 70's Vulcan Continental; it was old then and the plumber took the mick out of it when he came to replace valves.
  3. D

    REALLY replace PCB? Vokera Comp.HE 25. Please help (cold Xmas ahead!!)

    Well Vulcancontinental, you appear to be a F))King superstar!!! A virtual bottle of Hungarian Schnapps to you! Was no continuity at hi-lim stat. So I shorted it out and the fan runs and into ignition. Let's see if she works fine once all is back together. I assume, for safety, that I should...
  4. D

    REALLY replace PCB? Vokera Comp.HE 25. Please help (cold Xmas ahead!!)

    Vokera's fault finder is telling me to replace the PCB ...but many of the outcomes on this fault finder give that guidance... I am of the view that a new PCB will NOT solve this issue. Unless it is a total coincidence with the fault following a drain/refill. I need someone who is very...