    Tado support have now got back to me, it appears that the issue has now been resolved. I wrote a summary of what I'd done where I was, and I got the message back: "I have un-linked the RUxxxyyyzzz (Upstairs) from the Extension Kit, it is independent now." And it does indeed seem to be heating...
  2. D

    Danfoss TP9000, TP5000 & Smart Heating

    Thanks @stem, I’ve logged a ticket with Tado support.
  3. D

    Danfoss TP9000, TP5000 & Smart Heating

    So I've now installed the additional thermostat in place of the TP5000, wired as per above. Strangely (although I'm not completely surprised) it's controlled the radiators on the ground floor, it's as though the wiring hasn't necessarily made a difference. I'm going to try various temperature...
  4. D

    Danfoss TP9000, TP5000 & Smart Heating

    Excellent @stem, and will the Tado just recognise that it’s suddenly controlling another zone? As in, i assume it’s now sharing control of the ground floor but connecting the wires will stop this ground floor control and the thermostat will begin control of the wired zone (upper floors)? Happy...
  5. D

    Danfoss TP9000, TP5000 & Smart Heating

    Thanks for the clarification @stem. So I’ve purchased the Tado Extension Kit, Smart Thermostat Starter Kit and an additional Smart Thermostat. I replaced my TP9000 with the Extension Kit and Starter Kit in no time at all, it really was a breeze and the help here and on Tados website made it...
  6. D

    Danfoss TP9000, TP5000 & Smart Heating

    Thanks @stem, I may get the v3 Tado and give it a try.
  7. D

    Danfoss TP9000, TP5000 & Smart Heating

    @stem That’s absolutely great, thanks for taking the time to write that. Would it be fair to say that the Tado is the only solution that would mean I have no need to place an additional device near my cylinder (or additional cabling to my cylinder)? It seems that the wires presented to the...
  8. D

    Danfoss TP9000, TP5000 & Smart Heating

    So looking at the wiring diagram (attached), I think I can see why I might need an additional Heat Link (Nest) / receiver (Hive). The TP5000 appears to connect directly to the cylinder and so I need some way of closing that circuit. With only two wires going to the TP5000 (Live & Br into...
  9. D

    Danfoss TP9000, TP5000 & Smart Heating

    Hello all, I'm thinking of buying either Tado, Hive or Nest for my house. I live in a relatively new build 3 story townhouse in the UK with the Danfoss TP9000 thermostat / hot water programmer on the ground floor next to my Ideal Logic 15 boiler, a Danfoss TS2 sensor in the living room. Then...
  10. D

    Hive and Danfoss TP9000 self install

    I’m just looking into various smart systems and toying between Nest, Hive and Tado. That aside, it sounds like you have the same existing setup as I currently have. The TP9000 replacement sounds relatively straight forward in as much as there are lots of other posts and comments of people doing...
  11. D

    Replace Danfoss TP9000, TS2 & TP4000 with Tado

    Im in the same boat as you Dan. About to purchase so keen to understand if it will work as I’d hope. Thanks