  1. M

    Slow going - my double storey extension build

    I certainly don't miss block laying in october by work light. Looks good progress
  2. M

    Brick or concrete garage

    I built a cavity wall insulated garage with a tiled roof, which internally measures 4.5m x 6.6m for under £10k. Although that's mostly materials only virtually no labour. Its not finished yet but i expect finished will be around £10k https://www.diynot.com/diy/threads/garage-self-build.532254/
  3. M

    Slow going - my double storey extension build

    Looks very impressive, not sure i'd have the confidence to be fitting a steel into an existing wall to make a new opening... I'd be far too worried about the house falling down!
  4. M

    Smart mcb?

    wouldn't it be safer to use a good quality contactor to switch the high current load on and off then use a wifi relay to switch on the ~1w load of the contactor. rather than trusting something of amazon to switch 32+ amps such as this...
  5. M

    Workshop Build

    looks great, whats the reason for such large doors?
  6. M

    Workshop Build

    I think it looks good with the overhang as it is, although would make fitting guttering difficult to say the least
  7. M

    Safe zone, is this allowed?

    Thought so, as if you ever removed the double socket you'd remove power to the fused spur
  8. M

    Safe zone, is this allowed?

    Hi all, So i know safe zones are created at straight lines from an outlet, but can the following be done Red shows route of ring main, and yellow shows proposed route for a fused spur
  9. M

    Garage Self Build

    Hi noseall, This was to give 2.4m high walls internally after the roof trusses are overboarded with 50mm PIR and 12.5mm plasterboard. Also it was required to clear the topbox on the roller door. It also gives sufficient room for a mezzanine storage area over the store room
  10. M

    Garage Self Build

    So now we have a door Will need to attack the unlevel floor with a grinder to get the door to seal all the away across. little bit of light showing in the middle Fence modified and refitted Will probably end up replacing the very weathered fence panel once i get a few off cuts of decent timber
  11. M

    16amp blue socket wired off a socket spur

    I'm going down the 3rd party approval route however the guy I used when I rewired the house is no longer doing it. But as long as I get it inspected before the plaster goes on whoever does the 3rd party approval can still check cable routes and if required I can make any modifications.
  12. M

    16amp blue socket wired off a socket spur

    Nope still here. Tbh I did stop reading after page 1 and carried on with my first fix it was only when I stopped I realised things had digressed somewhat although this isn't my first time posting in the electrics section of this forum so I'm not surprised. Unless it wasn't clear garage is being...
  13. M

    16amp blue socket wired off a socket spur

    The reason for my first question was I was hoping to save on cabling by spuring it. But as you said that is not good practice I will now run it as a separate circuit
  14. M

    16amp blue socket wired off a socket spur

    Thanks. As I said I will wire it on its own 16amp circuit
  15. M

    16amp blue socket wired off a socket spur

    I'm aware that's why I'm fitting a 16amp socket
  16. M

    16amp blue socket wired off a socket spur

    It is supplied by 3 core 6mm SWA. It is connected in the house to a 40amp MCB. The garage has a metal clad split load RCD CU
  17. M

    16amp blue socket wired off a socket spur

    I'm wouldn't be running a commercial welder it would be something more like this https://www.screwfix.com/p/impax-im-mig-150-20-150-150a-mig-welder-240v/17499#product_additional_details_container
  18. M

    16amp blue socket wired off a socket spur

    Ok another question then. I want to have 2 16amp sockets in the garage so I can move the welder about. Can these both be wired as 2 separate radials from the same 16amp MCB? I know this means they both cannot be used at the same time but I'm a little stuck with space in the CU
  19. M

    16amp blue socket wired off a socket spur

    What is the reason as the 2.5mm twin and earth can supply in excess of 16amp and it it's not impossible for someone to plug in 2 2kW appliances into a double socket that is on a spur. Dispite the fact that you shouldn't. Presumably it's because the blue 16amp plugs don't have Fuses?
  20. M

    16amp blue socket wired off a socket spur

    Hello, Is it allowed to wire a blue 16amp socket as a spur off a ring main? Would be used for a welder