Search results

  1. L

    Box frame encased in concrete.

    Length is 7.15 m Think the beams were pushed up into the floor boards. Stanchions were not measured on site but by the plans. They were trying to do us a favour by pushing the top beam up. But didn’t account for longer stanchions.
  2. L

    Box frame encased in concrete.

    Structural engineer plans note Provide305x305x97UC bottom beam to box frame, laid along existing rear wall, below ground floor level. Bottom beam to be wrapped in D49 wrapping mesh & encased in 100mm concrete surround. The ground beam is down to the existing foundations so it’s not...
  3. L

    Box frame encased in concrete.

    Do I need a revised plan, so that we are covered if there are any structural faults.
  4. L

    Box frame encased in concrete.

    Hi Seeking some advice. Had a box frame steel beam put in for a new extension. A trench was dug for the bottom beam. The top beam was lifted higher into the floorboards to create more head room. The base beam has been filled with concrete. There is no way 100mm of concrete can fill the...