    Ideal Mexico - Intermittent Main Burner Lighting Issue

    Sorry Namsang my last response was badly worded. It was my intention to hang on to the new valve until I had a replacement solenoid, and then return the valve with it's original solenoid. Thanks again
  2. B

    Ideal Mexico - Intermittent Main Burner Lighting Issue

    Actually I think Namsag is correct. I had already gotten hold of a replacement gas valve, but after reading Namsag's post I decided to take the solenoid off the new valve and fit it to my existing valve, and hey presto it works. The main burner stays lit until the thermostat operates. So...
  3. B

    Ideal Mexico - Intermittent Main Burner Lighting Issue

    Thanks for the speedy replies guys. I'll take your recommendations, get hold of the valve and find a Corgi fitter to fit it for me. Just for your reference the valve is a Honeywell V4700E1031 which has Khaki Green button on it. So far the cost of a direct replacement is looking like...
  4. B

    Ideal Mexico - Intermittent Main Burner Lighting Issue

    I have a Ideal Mexico Super 2 CF60 Boiler. It has developed a fault which I originally first noticed as luke warm radiators and tepid hot water. On further Investigation I noted that the main burner ignites, runs for a minute of two and then stops leaving the pilot flame running. The main...