  1. Stuw101

    Solidor front door.

    Hi has any one had a solidor front door fitted recently please? I have one done and got a few issues. Would there be any one kind enough to pop up a picture of what the wool pile seal looks like on your door frame. This is the fluffy seal that runs around the inside of the frame to block...
  2. Stuw101

    New Tado heating systems

    I want the open plan room kitchen diner longe to act as one zone and the rest of the house to call for heat when needed. Rather than buy three trv in the open plan kitchen diner lounge I wondered if an additional room stat sat in the lounge part would suffice the lounge Always needs the most...
  3. Stuw101

    New Tado heating systems

    Hi, I have just installed a Tado heating smart thermostat and couple trv. I had to go with Tado as only had two wires in my old cm907 thermostat to use. So far so good and install was very simple. I have an L-shaped open plan living room diner. I have three rads on there. In order to keep...
  4. Stuw101

    Replace a Honeywel CM907 with a Nest Thermostat v3

    Hi thanks so can you set the different tempratures in rooms independently with the app from your phone and control the additional trv tempratures without the extension kit? I thought that was just for water control? I have a logic 35 boiler. I have ordered the harness to make it open therm...
  5. Stuw101

    Replace a Honeywel CM907 with a Nest Thermostat v3

    The best looks hideous though and can’t find much on trv’s from them. After much research today online and via companies Tado apparently will work as well but they won’t tell you how to wire it until you buy a kit then they send you the instructions on how to do it. They have assured me I only...
  6. Stuw101

    Replace a Honeywel CM907 with a Nest Thermostat v3

    I have similar wiring in my new build. I have the cm907 thermostat and want to switch to a smart system hub. The wires are live, switched live and an earth behind the stat. There is a single spare wire not used in the look cut at both ends. Is there any system that will connect straight to this...
  7. Stuw101

    Advice on converting a Honeywell CM707 thermostat to Drayton Wiser

    That’s ok. The grey wire in mine is cut. I have have checked it at the boiler fused switch end. It is also cut in that. I am guessing that means the grey wire could simply be connected to a live feed in the fused switch area making it a live feed at the thermostat end and would therefore make...
  8. Stuw101

    Replacing Honeywell CM707 with HIVE

    Did you figure this out? My wiring is similar in my new build. I have a cm907 I want to replace it with a Drayton wiser hub. Have w live, neutral, earth and grey wire cut off in the back of the thermostat box. Must be a way of getting that grey wire to provide what’s needed to power the hub? I...
  9. Stuw101

    Advice on converting a Honeywell CM707 thermostat to Drayton Wiser

    Did you manage to sort this out mate? I have a new build house. It has the cm907 connected to the boiler. Behind the cm907 there is a live, earth, neutral and a grey wire that has the end cut off and just tucked in. I have tried to wire it by putting a loop between live and pin 1 on the wiser...