Search results

  1. W

    GxRemoteControl: unable to connect to panel invalid connection password

    You need to set up the notifications initially in the app and register for the service, quite straightforward as I recall. Not sure about the next step as only needed the App for some controls, but I think you need to set the events and notification route in option 56. Galaxy Guy is the one...
  2. W

    GxRemoteControl: unable to connect to panel invalid connection password

    HI Steve, Yes, you need to set the outputs in 53, select output, option 6 control, & set mode for toggle or trigger and when you next go int the app the controls appear like magic!
  3. W

    GxRemoteControl: unable to connect to panel invalid connection password

    Yes, I have now added a RIO where the outputs are controllable and robust as you say. Just checked the setting of op1 & 2 on the main board and dohhhh! still had them set as pulse which is exactly what they were doing! As for the trigger board, I have taken it out as I do not need the...
  4. W

    GxRemoteControl: unable to connect to panel invalid connection password

    So, In case anyone else has been trying to work this out, the outputs on the trigger header of Galaxy panels is not supported, so that's sorted that one. Still trying to work out why the output from main board o/p 1 & 2 is so unpredictable. Thanks for all your help Galaxy_Guy, appreciated. Tony
  5. W

    GxRemoteControl: unable to connect to panel invalid connection password

    Just though I would update you. I can program o/p 1&2 for control and can see them on the GX app, but it doesn't seem to matter whether the o/p's are programmed as pulse, latch or reflex the output is a short pulse on switching on and another short pulse when the control on the app is switch...
  6. W

    GxRemoteControl: unable to connect to panel invalid connection password

    Cheers, I thought as much. It's not too bad as the system is mainly only being used for DCM door access and the idea was that I could use the GX remote to release/close the gate/door remotely. I could try building a link zone but it seems it would have been easier just to use the control on...
  7. W

    GxRemoteControl: unable to connect to panel invalid connection password

    I could reflash the panel with the latest firmware via the USB connection, but that would be a last resort as I have no way to save the configuration so that would mean a total reprogram :-(
  8. W

    GxRemoteControl: unable to connect to panel invalid connection password

    HI, Thanks for the quick reply, really appreciate that. Yes only two on the main board but I have added the trigger module as well. I have enabled the module and I can see all 8 o/p's in programming but I can only choose one of the predefined output type and chose custom A, but for some...
  9. W

    GxRemoteControl: unable to connect to panel invalid connection password

    Hi Galaxy Guy, You are the font of all knowledge when it coms to Galaxy stuff! I have a Flex50, firmware 3.37 (it seems it originated as an ADT panel although I did not know that at the time of purchase). I am trying to configure the panel to work with GX remote, set most thing up ok with the...