    My original plan was to install 3x air conditioning units (air to air heat pump) after nearly running out of oil at the peak of winter with the added benefit of cooling. I had already run this past my neighbours and these outdoor units are not going to be visible from their property, and our...
  2. I

    Sunvic to Netatmo Thermostat

    I think I have sorted this out. All the problems were due to the Live and N being switched around from the mains switch to the programmer, which was causing a lot of complexity. Once I wired them in the correct way (Black wire to N and Red to L from the mains to programmer). The yellow...
  3. I

    Sunvic to Netatmo Thermostat

    This is what I found The mains power switch works perfectly :D The wall thermostat (Sunvic LX 2356) 1. yellow with red sleeve (has power when thermostat is off) 2. Blue with red sleeve ( has NO power when thermostat is off) 3. Red has no power when the thermostat is off When the thermostat is...
  4. I

    Sunvic to Netatmo Thermostat

    Does that mean, the HW and CH have been wired the other way around? o_O Is there an easy way to check if the wires from Terminal 1 and 2 of the programmer are the same going into thermostat? Never had to do this in the past. Also do I need to do anything about the Neutral terminal on the...
  5. I

    Sunvic to Netatmo Thermostat

    Yes the thermostat pic is the room stat. I first checked with a tester, then used a multimeter to check for voltage across the various terminals The Neutral I am referring to is in the programmer ! When the Hot water is on I get voltage on Terminal 3, but when CH is on I get voltage on both...
  6. I

    Sunvic to Netatmo Thermostat

    We are in the process of moving house and currently have a Netatmo thermostat along with a bunch of radiator valves. Our new home has Oil central heating and hot water. There are two thermostats - One in the hall way and the other next to the boiler(which is in the garage).20201223_132521 by...
  7. 20201226_164329

    20201226_164329

    2 port valve
  8. 20201228_140503

    20201228_140503

    CP715 Danfoss
  9. 20201228_140506

    20201228_140506

  10. 20201228_140522

    20201228_140522

    Danfoss CP715
  11. 20201228_140528

    20201228_140528

  12. 20201223_131703

    20201223_131703

    TLX 2356
  13. 20201223_132521

    20201223_132521

    Sunvic
  14. 20201224_164526

    20201224_164526

  15. 20201224_164533

    20201224_164533

  16. 20201224_174554

    20201224_174554

  17. 20201224_174609

    20201224_174609

  18. 20201224_175743

    20201224_175743

    Danfoss CP715
  19. 20201226_120449

    20201226_120449

  20. 20201226_120454

    20201226_120454

Back
Top