    Water hammer from mid position valve

    If the pump was the only thing changed before the noise started then it can only be pump fitted the wrong way round or a worn out 3 way valve . Could also need the bypass opening a little if there is one .
  2. J

    Waste through studs?

    If it’s non Structual it should be ok . But basin only requires 32mm waste pipe so if you drill say 34mm the smaller the hole obviously the better .
  3. J

    Water hammer from mid position valve

    The bang is probably a worn out three way valve . When they sometimes make a bang when springing back to hot water mode when heating shuts down . That is most likely when it does it , and the flow of water through it makes the ball shut the heating port very suddenly causing a bang , if you have...
  4. J

    New boiler installed but radiators cold downstairs

    The filter should be where it is for best protection of the boiler . I know they are unsightly but that is the best place for it
  5. J

    New boiler installed but radiators cold downstairs

    If you only have 3 radiators upstairs and two downstairs I’ll be suprised if balancing is the issue. Make sure the pump valves are fully open and if any isolation valves on the boiler which if it’s a system boiler there will be and if it’s a combination boiler there will be make sure they are...