Search results

  1. Matthall03

    Alpha Intec recurring E96 error

    I haven’t had any further issues
  2. Matthall03

    Alpha Intec recurring E96 error

    Yep been no issues since the repair. Hope I’m not tempting fate by posting this. oh yeah - what do you think the issue is in your case ?
  3. Matthall03

    Alpha Intec recurring E96 error

    The part was £180 from Alpha - did come the next day though . Will post back in a few days to let you know how it’s going .
  4. Matthall03

    Alpha Intec recurring E96 error

    Hi there - hopefully mine has been fixed by replacing the burner plate. My plumber phoned Alpha and they said the error is normally that . The replaced part didn’t look to clever, so hopefully it’s now rectified! many progress with yours ?
  5. Matthall03

    Alpha Intec recurring E96 error

    Sorry i made a typo - I do have the same error code . Edited post to correct .
  6. Matthall03

    Alpha Intec recurring E96 error

    Hi there , many progress with this ? As I have the same issue, the error is now being experienced more frequently . I had a gas engineer check it out a few weeks ago, he straightened the flue and serviced the boiler and was ok for a few weeks . E96 displays and the hot water goes and the only...
Back