  1. C

    Spur in 1.5

    Having read all the helpfull comments I decided I would change the cable to 2.5mm, very glad I made this decision as this is what I found buried under the plaster........
  2. C

    Spur in 1.5

    Thanks for all of that John, point 1 does anyone make a single socket to fit a double back box? Point 2 not sure where I could easily fit an FCU point3 looks like I will have to rip it out and start again, not sure whether it's in conduit or something else as it runs horizontally. Won't be...
  3. C

    Spur in 1.5

    A double socket and yes its in 4mm T&E
  4. C

    Spur in 1.5

    32amp MCB
  5. C

    Spur in 1.5

    It's a 32amp mcb
  6. C

    Spur in 1.5

    Hi there, just moved into new property and my predecessor has installed a spur off the radial circuit in what appears to be 1.5mm T&E, as I only intend to ever run the tv and sky box of this socket can I leave it as is or do I have to rip it out and replace with 2.5mm or even 4mm?
  7. C

    Lighting

    All sorted now, not sure why there was a bum connection they've been working for years. Changed the one junction box for two now so less cables in there and all is fine. Thanks again for your input.
  8. C

    Lighting

    Just a bog standard mains test screwdriver
  9. C

    Lighting

    Hi folks, I have a junction box in the loft that feeds loft lights in two different lofts, a light in the toilet and the bathroom light. Up until last Saturday all four lights have worked perfectly for years, as of Saturday the bathroom light and one of the loft lights no longer work, toilet and...
  10. C

    TreviTherm shower

    Thought it might be, having looked at replacement costs might leave a while longer until it becomes a nuisance.
  11. C

    TreviTherm shower

    Hi folks, we have the above shower which has been in situ for over 20 years. Recently when first turned on the water heats up and then, only occasionally, will go cold for a few seconds before returning to normal and is OK for the rest of the shower. Any ideas from you great minds?
  12. C

    hot water cylinder

    Thanks for your responses, think I may have been a little premature as everything seems ok now,
  13. C

    hot water cylinder

    Cold feed is on the opposite side of the cylinder, been feeling the pipework where it goes into the cupboard/loft where the boiler is and where it connects into the return pipework for the whole system, just thought that the return pipe would have at least got warm. Think I might open the drain...
  14. C

    hot water cylinder

    Have turned C/H off have H/W on constant turned stat to max but boiler only runs for a very short while and keeps repeating itself but return pipe remains cold.
  15. C

    hot water cylinder

    Thanks for that, boiler fires up for a very short time, maybe a minute max, then shuts off, keeps doing that whereas when C?H calls the boiler runs for a long time, could it be an airlock
  16. C

    hot water cylinder

    Should the return pipe from the hot water cylinder be at least warm? Have cleaned C/H system and all rads are lovely and hot, the 3 port valve appears to work making the feed to the cylinder hot but the bottom return pipe remains cold and the hot water doesn't get very hot. Any ideas what the...