Search results

  1. M

    Shower not reaching set temperature

    Phoned Triton last week and I made it clear I was very unhappy with the service and I would of been better off purchasing from a retailer as opposed to the manufacture as I could of return the faulty item. (with them you have to wait for a service engineer to come out and inspect) Triton...
  2. M

    Shower not reaching set temperature

    So had the shower off the wall again. The filter looks clear to me (gave it a blow) as i couldnt see how to remove it.
  3. M

    Shower not reaching set temperature

    Bugger means messing about with the compression fitting.
  4. M

    Shower not reaching set temperature

    Flowrate at setting 6 was around 10 seconds. Wheres the shower filter? I would imagine its clean as the showers not even that old.
  5. M

    Shower not reaching set temperature

    Powered back on. Turned on hot (setting 6) Waited around a minute and the shower did not heat up. Hot at the very start, then went to luke warm and then freezing cold. Turned setting to coldest for 3 seconds then back to temperature 6. After around 40 seconds the shower heated up but this time...
  6. M

    Shower not reaching set temperature

    So all the wiring looks fine. Removed from the terminal blocks in the shower and re-inserted/tightened. Power back on. Turned the shower on hot (setting 6) and heated up in around 7 seconds. Turned then shower off. Heard the tco click around 20 odd seconds. Power off to to the shower...
  7. M

    Shower not reaching set temperature

    Hi not as yet, not had chance to double check the wiring and switching to max hot and back down again. I did use the shower this morning and it worked as it should straight away.
  8. M

    Shower not reaching set temperature

    So this morning (after leaving the power switch left on overnight/and temperature setting the same) the shower took 90 seconds to heat up surely something is not right
  9. M

    Shower not reaching set temperature

    This morning I took a shower. (left on previous settings 6) the shower took 15 seconds to heat up. Turned off afterwards at the shower and then at the switch. Over 6 hours later thought I'd try again to see. This time (same settings) the shower took 90 seconds to heat up. As per the previous...
  10. M

    Shower not reaching set temperature

    Yes 15 second cold runs before each hot run. 4 times in a row. (did not switch off the shower at the switch outside the bathroom)
  11. M

    Shower not reaching set temperature

    OK so tried what was suggested. Setting 6 on cold for 15 seconds then off. Power on hot setting 6 and heated up in around 8 seconds. Repeated this process 4 times and worked as 8t should. Turned the shower off at the wall (outside bathroom) and left it. Went back a few hours later for an...
  12. M

    Shower not reaching set temperature

    What would be the best way to clear an air lock in the shower? I've tried going from full power slowly turning to hottest setting so many times I've lost count now. Whilst doing it with the shower on "cold" the water does not splutter but whilst it's on "high"(temperature/normal operating)...
  13. M

    Shower not reaching set temperature

    So Turned on the shower on coldest setting then turned to 6. Took 80 seconds to start to heat up at which point there was a spluttering with the water. Turned to maximum and again as before water spluttered then went redhot for a short duration and then cold again as before. No flickering...
  14. M

    Shower not reaching set temperature

    Turned the shower on whilst it was on temp 6 took about 40 seconds to heat up. Turned the temperature upto maximum. Went red hot and then back to cold. Took around 30 to 40 seconds to heat back up to maximum temperature. Funnily enough when starting to heat back up the flow started...
  15. M

    Shower not reaching set temperature

    I'll give that a go thanks. Its an 8.5kw shower.
  16. M

    Shower not reaching set temperature

    So I've done the following. (with shower head attached) 1. At temperature 6 (first hottest, temperature I like to shower with) took 10 seconds for 1 ltr. (heated up to temperature) 2. Coldest setting took 7 seconds for 1 ltr. 3. At 6 took 10 seconds (did not heat up) 4. Bath tap (same...
  17. M

    Shower not reaching set temperature

    The issue with that is Triton will charge £150 if the issue is found not to be with the shower, which sadly is something which I cannot afford. The shower was supplied brand new directly from themselves. Could an air block be causing the issue? As the pressure on both taps (same feed) is plentiful
  18. M

    Shower not reaching set temperature

    Hi, No it didn't happen with the old shower. And no lower pressure warnings showing. The things I have changed has not made any difference to the pressure at the taps from what I can see. Saying that the pressure from the taps (basin & bath) is plentiful enough, good pressure.
  19. M

    Shower not reaching set temperature

    So to cut a long story short (ish) my old electric shower Triton Madrid was playing up. The shower its self was 10 years old so I decided to just replace it with a like for like equlivant Triton Cara. The issue I have is that the shower does not heat up to the desired temperature unless i turn...
Back