Search results

  1. C

    biasi m90e.24s

    my boiler just stopped running,turn water on red light on water valve glows but it does not fire up,no ignition,turn water of but pump keeps running red light still on
  2. C

    biasi m90e.24s

    many thanks to Tony and all the people who replied to my problem boiler,could you please explain it in English, i am not spanish i just live here,once again many thanks for taking the time to reply. chris
  3. C

    biasi combi boiler

    thanks for the reply to the problem of biasi boiler,it is a Biasi M90E.24S i have changed the magnetic flow switch still the same,ie pulling DHW flow switch foreward slightly so little red light comes on, hot water side works ok,(central heating ok)any more info on pcb, and the other reply they...
  4. C

    BIASI 24S COMBI BOILER

    MY BIASI 24S COMBI BOILER DOES NOT FIRE UP ON HOT WATER(OK ON C/H SIDE), BUT IF I PULL THE MAGNETIC FLOW SWITCH SENSOR FORWARD SLIGHTLY ON THE FLOW SWITCH SO THE RED LIGHT COMES, ON IT WORKS,CAN ANY ONE HELP.
Back