  1. S

    Inhibitor

    Hi,if anyone can help,is there a certain type of inhibitor you need to use if adding to a sealed system? Anyone know the best type? Any help would be great,cheers
  2. S

    Pipe run

    Hi to all,i'm about to install an electirc shower and was wondering what insulation the cold main would need? I plan to chase out an internal wall (this devides the bathroom and a bedroom),the internal wall is 3 inches thick,the pipe will eventually be plastered and tiled over,would 9mm foam...
  3. S

    Cloakroom suite

    Ok,cheers mate
  4. S

    Cloakroom suite

    Cheers,do you know much on the building regs,would i have to get the all clear from them?
  5. S

    Cloakroom suite

    Hi to all.I Have a customer who aswell as wants a new bathroom suite fitted also wants a toilet and basin fitted downstairs in the cloakroom.The plastic 4inch soil comes down in a cupboard,what i'm hoping to do is cut a tee in for the toilet and drill out the side of the tee for the waste...
  6. S

    Shower valve

    HAHAHAHAHAHA,Knup is what i call my cat.She's super.
  7. S

    Shower valve

    Its comes from a balanced supply on a unvented cylinder,and yes where i live does generally have hard water,It isnt a mira but the valve moves left to right which is on and off.Note that it has been installed for five years now,it wouldnt be a straight forward washer change then,if it was this...
  8. S

    Shower valve

    Hi to all.I have a shower that constantly drips,it's to do with the valve that you operate it with,its a lever and i can only think of two things it could be that ,1.the washers gone or 2. muck has got in behind the valve and this is why it won't shut off propely.Im a bit dubious of taking it...
  9. S

    Isolation valves

    The water regulations say that its compulsery to fit isolation valves on float operated valves,other appliances are optional but i'd fit them,makes it a heck of alot easier
  10. S

    Would this solve the problem?????

    pk,cheers.I'm on the case :o
  11. S

    Would this solve the problem?????

    Sorry,i forgot to add that the basin and sink are fed in 15mm which is teed off that 22mm pipe and you can run those hot for hours.They dont ever go cold,so am i still assuming that there is a problem with the boiler??
  12. S

    Would this solve the problem?????

    Hi to all.I have a customer who is complaining about a lack of hot water to the bath.They have a combi boiler.There is a 15mm tapping on the boiler for the hot pipe however the hot comes from the boiler in 15mm and then about a foot on has enlarged to a 22mm pipe.This then goes off to feed the...
  13. S

    Plumbing Course

    Dedication is a must.Your heart has got to be in it to really do well.I started my plumbing course in 2003 when i was 19.A year into that course and i got in with a company for 2 years and learnt a heck of alot,and beleive me there is so much to learn,not just theory but practically too.Give it...
  14. S

    tricky soil pipe

    nice one.Looking at the assortment they've got i'm laughing,i never realised they did so many different types.Thanks again.
  15. S

    tricky soil pipe

    I am looking at fitting a new bathroom suite for a mate but have come up against a problem in terms of the toilet.The existing soil comes in through the wall but to the side of the toilet and about a foot out from the back wall.There existing bog is one with a flush pipe and they are looking to...