  1. BobSlayer

    Check of Drains layout - Can you join a vertical vent pipe underground?

    The alternative (below) would be to join the pipe down flow of the vent pipe in the utility - this was the solution suggested previously in this forum by Woody. However as you can see this will necessitate the vent pipe being in a different corner of the Utility - which is proving difficult to...
  2. BobSlayer

    Check of Drains layout - Can you join a vertical vent pipe underground?

    Hello there Can anyone see any problems with the drains plan below? (it is amended and updated from an earlier question) The question we aren't sure about re Building regs: Can the branch from the toilet join the vertical soil vent pipe? This join would be under the floor. "O" in Utility =...
  3. BobSlayer

    Drains Under Extension - limited room for Inspection Chambers / Rodding

    Super big thank you... still some head scratching to be done, but i feel we are getting there and I should at least be able to work out where I am digging x
  4. BobSlayer

    Drains Under Extension - limited room for Inspection Chambers / Rodding

    Hmmm OK I see - what would I need to do in order to retain the shower and sink as well as the WC? - Straight line directly line from the WC in the original position - with branches joining from the sink and the shower?
  5. BobSlayer

    Drains Under Extension - limited room for Inspection Chambers / Rodding

    Ah... very interesting Is there any reason you have removed the shower and moved the WC? - was there a problem with this set up as we really want a shower and WC here.
  6. BobSlayer

    Drains Under Extension - limited room for Inspection Chambers / Rodding

    Ahhhhhh super big thank you Woody - there is a pint waiting for you in Worcester! Sorry yes I knocked them up on an online programme with my limited skills! I can see I missed a few doorways. Cheers for the tips. We tried it here and it didn't work as well. Being at the front means it has the...
  7. BobSlayer

    Drains Under Extension - limited room for Inspection Chambers / Rodding

    Obviously this is an option - It could be possible to put an internal inspection chamber in the above mentioned utility room back of the kitchen? - do you think it is necessary? It seems that building inspectors / water companies are not keen on them as an option?
  8. BobSlayer

    Drains Under Extension - limited room for Inspection Chambers / Rodding

    Cheers, yes, there will be a utility room at the back of the Kitchen, between the kitchen and the new bedroom (converted from the garage) - I didn't show it here as it seemed to complicate the drawing. So the current plan is for it to go up and internal wall. My main concern is having enough...
  9. BobSlayer

    Drains Under Extension - limited room for Inspection Chambers / Rodding

    Hello We are about to extend our kitchen. Single story extension. I am scratching my head to make a pan for the drains. We have limited room for external inspection chambers and rodding points as our property and new extension will sit on the boundary on 3 sides. - The new kitchen will...