    Hot water only activates on certain taps

    Hi, Yes it has preheat, I'll investigate the diverter valve in the morning. It's getting too late for technical issues! I can definitely hear the water flow through the boiler when using the hot tap with or with out it fired. It's a strange one. But thank you both for taking time in replying...
  2. P

    Hot water only activates on certain taps

    Good idea, So the two taps that don't work, the shower and kitchen taps both take 10 seconds to fill a litre jug. So 6 LPM The bath and sink tap both take 6 seconds and does engage the boiler . So 10 LPM
  3. P

    Hot water only activates on certain taps

    It runs straight through from the main shut off valve from outside. It's only a meter away from the valve. The old tap had so much pressure it would spray all over the kitchen. It was connected via copper pipe and the new via the Flexi pipe, but it isn't twisted or at any funny angles.
  4. P

    Hot water only activates on certain taps

    Correct, it's now both the shower and the kitchen tap. Whereas the bath hot tap and the sink does activate it. It kicks in around 85% open. I'm assuming the pressure isn't good enough. But no idea how to fix it, currently.
  5. P

    Hot water only activates on certain taps

    Hi all, I hope everyone is well! I was wondering if anyone could point me in the right direction. I have a i-mini c24 combi boiler that was here when I move in to the flat in April. The boiler was only installed two years ago apparently. Ever since I've moved in the showers hot tap which is a...