  1. L

    Halstead finest platinum combi.

    Ordered the replacement fill loop valve should be here tomorrow hard to find now, mine is different as most look like they are compression fitted to a shut off valve then the flex hose, mine is a solid brass unit 300721 part, part of the main inlet valve assembly which unscrews off that and has...
  2. L

    Halstead finest platinum combi.

    Thanks, pressure up again overnight so just took off filling loop hose like you said and yes main brass valve passing the one you need a 7mm spanner to shut, hopefully by just replacing this one will do the trick as the other one is around £88 which is just a ball valve but comes with a brass 3...
  3. L

    Halstead finest platinum combi.

    Thanks for that will look them up, I replaced the heat exchanger again this morning and checked the expansion vessel pressure, expansion vessel 1 bar, slowly topped up system to 1 bar , put heating on for half hour and ran , cooled down later to 1.1 bar , checked a few radiators and the highest...
  4. L

    Halstead finest platinum combi.

    Replaced the heat exchanger again this morning going to see if this will sort it out. couple of questions if someone can help please, when is it best to bleed the system ie Radiators , hot when boiler running or cold ? And if I have to go down the new combi boiler route which is the best boiler...
  5. L

    Halstead finest platinum combi.

    Thanks for that very helpful!
  6. L

    Halstead finest platinum combi.

    Does anyone know if a heat exchanger from a halstead finest, gold, ace high,would fit a finest platinum? Looks like you can buy loads for the other models for as little as £20 but not the platinum OEM number is 451011 in my book with boiler.
  7. L

    Halstead finest platinum combi.

    It’s a possibility as I have two, one in use and one I use to swap over and then I descale it and use next time, I generally have to change it every on a yearly basis as it gets blocked, the pipe work wasn’t properly flushed when it was fitted years ago.
  8. L

    Halstead finest platinum combi.

    Hi I was just wondering if anyone can help please, my halstead finest platinum boiler which is getting on a bit has a pressure problem, I swapped over the heat exchanger as I do from time to time as it blocks and normally no problem, but this time I checked the expansion tank and was a little...
  9. L

    Scantronic 9600 Keypad cleaning

    Took it apart with the wires still connected, cleaned key pad on pcb , clean rubber buttons, put back together works superb now thanks for all your help .
  10. L

    Scantronic 9600 Keypad cleaning

    Brilliant thanks will give it a go cheers .
  11. L

    Scantronic 9600 Keypad cleaning

    I was thinking of trying that tbh but couldn’t see how the pcb came free from the outer case, undone a couple of screws , then a clear cover comes off but not sure whether to try and pry the board up , is it clipped in somehow ?
  12. L

    Scantronic 9600 Keypad cleaning

    No, I don’t have the engineer code, it was fitted 16 years ago and have lost touch with the guy who fitted it . May have to pay someone to come out but looks easier enough to do if I can stop the alarm going off !
  13. L

    Scantronic 9600 Keypad cleaning

    I have an old scantronic 9600 alarm system which has been superb but recently the buttons on the keypad are sticking so I want to take it apart and clean it, I unclipped it and the tamper alarm went off so put the code in and that stopped but when I go to unwire the pad the alarm goes off and I...
  14. L

    Beko integrated dishwasher DIN15C20

    Ok thanks, least all sorted .
  15. L

    Beko integrated dishwasher DIN15C20

    Were the instructions they emailed you the same as I listed or I have I just found a different way of doing it ? Be good to know as like you say the manual is clear as mud . phil.
  16. L

    Beko integrated dishwasher DIN15C20

    Had this same issue, manual useless , beko customer support useless no one could help , but after a couple of days found out how to do it myself so this may help others. 1. Turn on , on control panel 2. Press and hold time delay and start pause button (together,same time ) and then release. 3...