Search results

  1. R

    Volts, amps, milliamps... and a tyre inflator

    Thanks, everyone, for your replies and efforts to search the right kit. Seems like I should just plug it into the car! Cheaper! Again, many thanks for your input.
  2. R

    Volts, amps, milliamps... and a tyre inflator

    Quick question on the above, due to my ignorance on the matter. Michelin tyre inflator, powered by in-car 12V supply. Power requirement stated in instructions: 7.5A/96 V under normal usage. Works fine, no problems. I'd like to get an adapter for it, the type that plugs into the mains...
  3. R

    Water or gas pipe?

    Yes, the house is detached and all ours. The main stop cock goes to the corner of the house, well away from the cellar pipe in question, so probably unlikely to be main supply pipe. That said, I wouldn't take the chance and certainly wouldn't drill into it without 1) knowing what it contained...
  4. R

    Water or gas pipe?

    Good point about supply pipe. Hadn't thought of that. Frightening thought!
  5. R

    Water or gas pipe?

    Thanks but how does this soundstick work? What do you mean by "apply"? Sorry if I'm being dim. Needless to say, no colour or tape markings on the pipe.
  6. R

    Water or gas pipe?

    Probaby a daft question but is there an easy (and safe!) way to identify whether a pipe carries water or gas? Want to tee from a 15mm water pipe in the cellar to supply ice making machine (mains pressure). Can see 22mm gas pipe and 10mm central heating pipes (old house!) down there. Have...
  7. R

    Garden sprinkler pump, etc.

    Thanks for that. The flow rate from the tap is 12.5 litres/minute. The sprinkler would use (at 4 bar) 18 litres/minute (good guess on your part!), so I figured that the top-up requirement (deficit) would be 5.5 litres/minute. Based on the sprinkler being in use for an hour at a time, I...
  8. R

    Garden sprinkler pump, etc.

    Hi, all. Not sure if this is a plumbing issue, exactly - but hoping someone can help. Have got average pressure to the outside tap but nowhere enough to power a decent sprinkler. I figured - simplistically - that I would just fit a (pressure) pump to boost the pressure/flow. I...
  9. R

    Garden sprinkler pump, etc.

    Hi, all. Have got average pressure to the outside tap but nowhere enough to power a decent sprinkler. I figured - simplistically - that I would just fit a (pressure) pump to boost the pressure/flow. I now realise that it isn't quite as simple as that, what with water bye-laws, break...
  10. R

    Crabtree SB6000

    I suspect that you are right. It does not show any identifier other than SB6000. According to Crabtree, the units first came out in 1992 but I don't know when they stopped making them. As such, I guess spares may be available for it but I do now wonder if it's time to get a new CU and have...
  11. R

    Crabtree SB6000

    Thanks for that suggestion. Time to find one, then! Richard
  12. R

    Crabtree SB6000

    Does anyone know if the main 100A switch on an SB6000 can be replaced with an equivalent RCD/RCCB (or whatever the correct terminology is)? I am advised that we need to add an 'RCD' following the building of an extension. Is it as simple as that or is a new consumer unit required? Thanks...
  13. R

    Baxi Instant 105e - part name unknown!

    Sorted. baxipoti was right. Simple hot/cold crossover on incorrectly marked (i.e. red/blue) pipes. Switched over and immediately fired up a treat. Let's hope it stays that way. Would like to thank everyone's input, especially baxpoti. Good luck to all. Cheers... Richard
  14. R

    Baxi Instant 105e - part name unknown!

    This is 100% my boiler, rob884. Sorry if I didn't make things clear. I'm an amateur at all this, as you can no doubt tell. The boiler was working, was then moved into the garage and the DHW did not work thereafter. I had had a similar problem with the CH diverter pin previously and so...
  15. R

    Baxi Instant 105e - part name unknown!

    Funny you should say that, baxpoti. Just come to the self same conclusion and spoken to the builder. Symptoms: Diverter pin does not move at all, irrespective of ANY tap that is opened in the house; Pipe that, I think, should be stone cold, is warm; Opening of any and all taps in the...
  16. R

    Baxi Instant 105e - part name unknown!

    Well, the DHW still isn't working after changing the valve differential, so maybe I do need one (whatever it is)! Sounds ominous. :cry:
  17. R

    Baxi Instant 105e - part name unknown!

    Dare I ask what an EXV is?!
  18. R

    Baxi Instant 105e - part name unknown!

    Anyone any idea why I've had to switch off the water at the main stop cock? The boiler's been moved today (not by me) and I would have thought that draining the boiler down and isolating the cold supply (as I've done) would allow me to have the stop cock open for water around the house. Am...
  19. R

    Baxi Instant 105e - part name unknown!

    Good idea, snorkel. Can't see where they're for at present but assume for the two pipes that are beneath the valve differential. Thanks, again.
  20. R

    Baxi Instant 105e - part name unknown!

    Thanks, corgigazza. Had just checked on partsarena.com and come to the conclusion that the part there is a 248734 (valve differential DHW) - exactly the same part as you thought. Thanks to all you helpful people. Just need to get the part ASAP now, so I can have some water in the house...
Back