  1. G

    Vokera Compact 24 - hot water on & off

    Part 3 of my monologue . . . . . Turns out CH isn't fine. Cuts out after ~15 minutes too. Just hadn't run it long enough previously to know it was an issue too. To try to rule out overheating, I took the temperature sensor off the side of the combustion chamber and left it dangling to the...
  2. G

    Vokera Compact 24 - hot water on & off

    Hello, Hoping someone might have some thoughts on this for me. Would be greatly appreciated. While the system was drained I removed and cleaned the DHW thermistor. Wasn't particulary dirty or anything (Got sprayed in the face you may be amused to hear. Because I'm an idiot and hadn't closed...
  3. G

    Vokera Compact 24 - hot water on & off

    Hi, My Compact 24 gives hot water for about 2 minutes then cuts out. CH works absolutely fine. Pressure etc all good. Dial turned up full for DHW. Tried reducing the flow into the boiler a couple of turns but no difference. Measured the resistance across both NTCs giving the following: DHW -...