Search results

  1. C

    Potterton -Performa 24 - Keeps coming on - Micro-Switch Prob

    thanks Tony, Yep, l should have followed your advice and not assume that the pcb was at fault. But lm pretty sure the guy rang for support first, as he turned up with the Micro-switch Job done and it all works, All you guys know your stuff on this forum, its a shame that lm just a...
  2. C

    Potterton -Performa 24 - Keeps coming on - Micro-Switch Prob

    thanks for all your help guys It was the micro-switch it cost me £85 in total all working now, thanks again
  3. C

    Potterton -Performa 24 - Keeps coming on - Micro-Switch Prob

    Tony, The Engineer has just called and has stated that he must change the Mircoswitch before considering that the main board is knackered. I have not much experience with boilers to be honest, but thanks with your comments to look at the microswitch He is on his way in the next hour, so...
  4. C

    Potterton -Performa 24 - Keeps coming on - Micro-Switch Prob

    sori for the late reply, had an engineer round to lok at the boiler rads warm up and so does the water microswitch is fine and the pin retracts when the hot water tap is run there is no moisture round the microswitch Had a guy come out this morning and he confirms that the pcb is...
  5. C

    Potterton -Performa 24 - Keeps coming on - Micro-Switch Prob

    Looks like the PCB is knackered The pin is extracting fine, no problems there, but the front panel of the Boiler is not responding, hence, the PCB is gone.... wat sort of price is a new one please, £65-80? thanks
  6. C

    Potterton -Performa 24 - Keeps coming on - Micro-Switch Prob

    Page 42, key 103 is the Pressure Differential Assy cant locate the micro switch assy in the document
  7. C

    Potterton -Performa 24 - Keeps coming on - Micro-Switch Prob

    just-thinking thanks for the reply, All that has happened recently is that the gas supply meter was changed. I have never opened the boiler up until today The boiler has an internal timer, which can switch the boiler on, off, time to certain hours. The clock on the timer is...
  8. C

    Potterton -Performa 24 - Keeps coming on - Micro-Switch Prob

    thanks for the reply Mickeyboy How do l do this - l assume that u mean turn the tap temperature down to zero. what should l do after performing this, I have done this and still the burner comes on and turns off Even if l switch off the timer, to the down position, the burner light...
  9. C

    Potterton -Performa 24 - Keeps coming on - Micro-Switch Prob

    Hiya All, First of all, great forum, I was wondering whether you can help me please, l have a Potterton Combi Boiler - Performa 24 After my gas meter was changed recently, my boiler decides to come on when it pleases (burner on neon light) , this can be every few minutes, then switches...
Back