Search results

  1. D

    Texecom Alarm Triggering after exit

    Thanks all, extending the settle time was indeed the correct solution on this one! Perhaps I had tweaked that by accident earlier on :rolleyes:
  2. D

    Texecom Alarm Triggering after exit

    Will give that a go tonight :) thanks. I'll set it to 8 seconds, as the PIR light seems to stay on for 7. Noting that the system seems to ignore the settle time and arm as soon as the door is closed!
  3. D

    Texecom Alarm Triggering after exit

    Hey all, I have a Texecom Premier Elite 24. The system sets as soon as the exit door is closed (which is what we would like). If I exit and the access PIR was triggered as I am closing the door, the system fails to set / the alarm sounds. In Wintex, the door is of zone type Entry/Exit 1, with...
  4. D

    Texecom Premier Wintex Tweaks

    Thank you @secureiam. You are correct, It's an Elite Premier 24. I've swapped the Area Bs to Area As so all under A now. I've set the guard attribute on the entry/exit doors, since I would like them to instant alarm under the night time part-arm 1. I read that on the forum, and this seems to...
  5. D

    Texecom Premier Wintex Tweaks

    Hey all, Thanks for the useful threads I've read so far here. My Electrician installed a Premier 24 and set it up with two areas (B upstairs/A downstairs), but part arms never worked correctly. He also didn't know about Wintex, so I have now registered and set that up myself via the...
Back