  1. A

    Comet Proline DWI 5212P

    Hi Does anyone know where I can get a User Manual for a Comet Brand Proline DWI 5212P Dishwasher or who it is that actually makes them and then just badges them Proline? Thanks
  2. A

    Built in Dishwasher problem

    Hi Hope someone can help, I have a built in Dishwasher made by Hygena its says Hygena Select, I cannot find an actual manufacturer name on it. M\c switched on and sounds fine fills with water and heatrs it up but then it does not start pumping water into the spinning spray arms so these do not...
  3. A

    Worcester Heatlslve 20/25 Oil Combi Blowing Internal fuse

    For the record managed to trace it to the Transformer on the Burner by disconnecting transformer in Control box and finding that the fuse did not blow. Removed transformer and it had got hot and swollen the plastic casing,changed transformer £35 and all okay.
  4. A

    Worcester Heatlslve 20/25 Oil Combi Blowing Internal fuse

    Hi , Hope someone can help. Noticed this morniong no heat from rads although they did come on earlier this morning, I checked the boiler and there was Power light and light for Heating so I turned up the thermostat and left for 5 mins. When I checked again there wer no lights atall including...
  5. A

    Wocester Heatslave 20/25 No Power Blowing fuse

    Hi Chris, There doesn`t appear to be any screwdriver slot inthem to turn. The one thats leaking is like a rectangle in shape but curved on either end. If their meant to be turned it would need to be done with pliers or mole grips. Tried to upload a pic of what I mean but cant see how to...
  6. A

    Wocester Heatslave 20/25 No Power Blowing fuse

    Hi Tony, Thanks for the advice. On furhter inspection there is a small flat seg type pice of metal that looks like some sort of screw in the union the pump goes into above the pump, this has asmall water leak coming from it, I think this is maybe what has damaged the pump. Think this is maybe...
  7. A

    Wocester Heatslave 20/25 No Power Blowing fuse

    Ok Chris, Thanks for your help, will get apump and try it.
  8. A

    Wocester Heatslave 20/25 No Power Blowing fuse

    Hi chris, I`m back now had to get a belt for the hoover, not my weekend! Right I went acroos the brown and the earth lead on the connector whcih is not plugged into the board by the way and again got 190 ohms if I go across the Neatral and the earth wire its infinity. If I get just the...
  9. A

    Wocester Heatslave 20/25 No Power Blowing fuse

    Hi Chris, Resistance readign I tookat the connector and reads 190 ohms. The Pum says Bosch on it but then below that it says Grundfoss Type UPS 15-60X18 pn 59526645 if that means anythinng to you. I have to pop out for an hour so will be back asap Thanks for all you help
  10. A

    Wocester Heatslave 20/25 No Power Blowing fuse

    Hi Chris, Thanks for you help Theres a bit of residue around the unions and on the back end of the pump where the 2 unions join into it but its definitley not wet and theres no trace of residue on the actual pump part itself. I am thinking maybe its just worn out. I have a meter, but do you...
  11. A

    Wocester Heatslave 20/25 No Power Blowing fuse

    Oh I just tried disconnecting the pump connector from the control board, when I do this the fuse does not blow and the boiler fires up ok when I switch HW on. Could it be a new pump is what is needed it has never had one in 5 years?
  12. A

    Wocester Heatslave 20/25 No Power Blowing fuse

    Hi, Hope someone can help. I have had the above boiler for 5 years. On Thursday night I put the heating part on for first time in 4 months. After a while I noticed only the first rads in the line had got warm and when I checked the boiler it was not running even though there was demand (It...