  1. B

    Floorboard thickness

    House built in 1981/2 needs new floorboards on landing. Is there such a thing as a standard thickness for T&G floorboards...and was there a standard when the house was built? I'm hoping that floorboards from my nearest shed will be the same thickness as those already down...or am I being...
  2. B

    Thermostat wiring

    The wiring diagram for your 6100C is at: http://content.honeywell.com/uk/homes/Catalogue/Heating%20Controls/2.11%20ST6100.pdf HTH Bixfoo
  3. B

    Thermostat wiring

    If your system is wired like mine was, you'll probably find that the white wire from the valve is wired into 4 on the connection block - this means that when the ST699 is set to "heating on" (i.e. 3 on the 699 is live) then the heating will run. I had to move the white wire onto 5 on the...
  4. B

    Thermostat wiring

    Assuming your 3-way valve is a "V4073A Motorised Mid-Position Valve", check out the figure on the second page of: http://customer.honeywell.com/Techlit/Pdf/95c-00000s/95c-10820.pdf I used this to fit my T6360. HTH Bixfoo
  5. B

    Please recommend a new condensing boiler

    Thanks for all the help guys. I'll look round for some quotes. Thanks again, Bixfoo
  6. B

    Please recommend a new condensing boiler

    Folks, Looking to replace boiler - Ideal Concord WRS255A 16kW from prehistoric times. All of my research suggests that this is nightmarishly inefficient. House is four bed detatched, boiler is in the garage. I'm guessing that the current Y plan heating system can remain, and I can just...
  7. B

    How do I add a thermostat?

    The 3-way is a Honeywell Sundial Y Plan, model V4073A1039 http://www.datasheets.org.uk/datasheet.php?article=3470346 Thanks, Bixfoo
  8. B

    How do I add a thermostat?

    Been looking at my central heating system, and my gas bill which is enormous. Looking at what I can do to get the gas bill down. Have noticed that although all the rads in the house have TRVs, there isn't a master thermostat anywhere. Conclusion is that the boiler must be running pretty...
  9. B

    Pipe noise after running cold tap/flushing toilet

    Cheers fella, will look into that! Bixfoo
  10. B

    Pipe noise after running cold tap/flushing toilet

    Run a cold tap or flush toilet upstairs. Stop running tap. Seconds later loud vibrating noise that persists for several seconds, eventually dying off. Started in the last few weeks. Anyone know what this is likely to be? TIA Bixfoo
  11. B

    Hot water in header tank - help!

    New to the forum...hope you guys can shed some light on this. Boiler is ancient Ideal WRS 255A conventional model. Has temp settings marked 1-6 on the boiler itself. Central heating and hot water run just fine at setting 3 (66 degrees C), but setting 6 (82 degrees C) results in hot water...