Search results

  1. R

    loop in lighting in modren house can I add

    Hya, The ceiling rose I'm replacing is on a two switches...thanks anyway.
  2. R

    loop in lighting in modren house can I add

    I am thinking that I'll need 3 core and earth between the boxes am I right ? And I'm goanna need to extented the loop out t&e to the last spotlight in order to keep all spots in a loop. If I don't extend the loop wire then my spots will be on a spur off the ciruit. Yea !!!!
  3. R

    loop in lighting in modren house can I add

    Is this what everyones is using now :shock: Really don't like the look of them :?
  4. R

    loop in lighting in modren house can I add

    Choc Boxes????forgive me they sound like somthing new, I thought you ment choc block. I don't like using choc block(not the way I was tought) But I assume it's something like that yea ? choc block but encased in a box yea! Well if they have cable grips as well as being boxed I can see...
  5. R

    loop in lighting in modren house can I add

    thanks, 8) dude if I wanted to use chewing gum I'd have asked at the corner shop. :P I wish to remove one ceiling rose and replace it with three recessed spot lights. Now I know that I can still use these double insluated lights....ok thats cool...but how to do it, would you suggest that...
  6. R

    loop in lighting in modren house can I add

    HI there dudes, 8) I foolishly bought some spotlights form B&Q without checking if they where double insulated or not. When I got home I realised straight away there where double insulated so...I'm now wondering how am I going to do it, and now I'm wondering if I'm allow by the regs to add...
  7. R

    Outside Flood light

    HI there again, I'am gonna have to chase a line down the wall to where I want to put the switch for the light. But does anyone know the minium and maxium depth, for chasing out a wall for a T&E cable & capping? As I seem to remember something about it, and it was to a certain depth...
  8. R

    Outside Flood light

    Dude Afew of the names ring a bell
  9. R

    Outside Flood light

    Kitson college in Leeds west yorkshire.
  10. R

    Outside Flood light

    :D Cheers mate thats right I'm abit rusty on this, I did a 236 part 1 about 10 years ago and I've never really a chance to use the knowledge.
  11. R

    Outside Flood light

    MMMM Dudes, I'just done some math and on this 300watt light is 1.25 Amps ok and I've 5x60 watt bulbs which gives me a total of 2.5 Amps. So If I use 3 Amp fuse in the FCU it'll work yes OK, but If I change any lights later upwards in wattage then what will happen? Will the 3 amp fuse blow...
  12. R

    Outside Flood light

    :roll: A big house.....Dude I said it's a new house and these's days they build them small. Anyway thanx man. Erm what do you mean by secrure spark? I figure that I'll take the power from the up stairs lighting ring (cos there's only about 5 lighting points up there and so I'll have...
  13. R

    Outside Flood light

    :wink: Cheers Dudes, Looks like I'll be wiring up to lighting circut in the loft and then run it down to switch and out to light. Whats the story with this artic flex stuff would I need to use some between the junction box and outside light? And do you think I'll have part P iusses later.
  14. R

    Outside Flood light

    Hya dudes, I'd like to install an outside 300w flood light on my new house. I\\\'m curently wondering if I should run the power from a ring main or internal lighting circut. Would I need to add a fuse spur and switch box in both cases? I've got a 300w flood light and some 1.5mm twin &...
Back