Search results

  1. S

    Vokera Linea 28 problems !

    :oops: :oops: :oops: :oops: Sorry Tony, you are right I should have made that clear it was a refurb (£70 cheaper than a new one !) Actually I found them really helpful, I also forgot to mention that I had to get a second replacement fan as well because I broke the positive lug off when...
  2. S

    Vokera Linea 28 problems !

    Hi Tony, Sorry for the delay replying. The supplier was Adlink at Hangar Lane London.
  3. S

    Vokera Linea 28 problems !

    Got the new PCB today and all works well. It seems the original problem was a faulty fan which blew the F2 fuse on the PCB. When I replaced the fuse and re-started it blew the relay on the PCB but not the fuse (although I did use an identical fuse !) I didn't realise that the PCB had blown...
  4. S

    Vokera Linea 28 problems !

    Thanks Paul, After all the people I pressganged into giving a view around here today that is exactly the concensus and after a few more diagnostic checks from the BG handbook it would seem to be the prob. I'll be off to get another PCB tomorrow ! I shall report back with the results so that...
  5. S

    Vokera Linea 28 problems !

    Thanks again for replies. I got a new fan and re-assembled the unit. I can get an ignition by closing the diff. switch but the (NEW) fan is still not powering up. When the wires are detached they are showing 240V but once attached to the fan motor they are showing 80V. So I know that the...
  6. S

    Vokera Linea 28 problems !

    Checked the fan and it didn't work when in the boiler casing. Took it out and juiced it up with 240. It worked for 3 seconds and popped ! Now I'm totally flummoxed !!!!! :shock: :shock: :shock: :shock: :shock: :shock: :shock: :shock: :shock: :shock: The fan is totally fu***d now...
  7. S

    Vokera Linea 28 problems !

    Many thanks for all the input. I'll be checking the pump, fan and gas valve today then probably venturing out for a recon. one of the above and probably another PCB. (Live and learn etc :oops: :oops: :oops: :oops: ) (Good mate of mine has two flats and a house let out.....He's a Postie ...
  8. S

    Vokera Linea 28 problems !

    Thanks for that guru. I've tried the search but no joy. I guess they are a fairly unpopular boiler. I would be very grateful if anyone else who had a similar prob could let me know. Many thanks.
  9. S

    Vokera Linea 28 problems !

    Thank you guru. I realised I may have killed the board with the fateful "pop" I heard. The only reason I changed it was that when I went through the several flowcharts which came with the boiler everything pointed to "change the PCB". But obviously with hindsight you are right and I should...
  10. S

    Vokera Linea 28 problems !

    Hi, First time post so please be gentle ! :shock: I have one one of the above boilers. 2 days ago I noticed it was electrically dead. I checked the electric supply etc. all fine. I checked the PCB fuses and 1 was blown (F2) I replaced it and the unit powered up ok but was and is...