    Vaillant 824 combi hot water

    If I take a reading as the wires come out of the PCB would that confirm the diagnosis?
  2. P

    Vaillant 824 combi hot water

    about 5 years old.
  3. P

    Vaillant 824 combi hot water

    With the tap off the red & black read 9.6.
  4. P

    Vaillant 824 combi hot water

    Hi guys, Ive got the meter. With black pin on the green wire & red on red I get a reading of 9.6. With red on black I seem to get no reading at all. Does this help us? Tony
  5. P

    Vaillant 824 combi hot water

    Hi, I've just done the self diagnostic tests again - d.22 DHW demand with tap open 0= no d.25 Hot water activation via warm start clock, with warm start off 1= yes d.35 Diverter valve position with heating OFF & tap open= heating system.?? I will need to borrow a meter and possibly a mate...
  6. P

    Vaillant 824 combi hot water

    Hi, I tried conecting the old diverter valve top to the connection rather than take the new one apart. The shaft spins when you switch the heating on & off but there is no response when you turn a tap on. I have a diagnostic panel on the front, which i think I tried before and found that the...
  7. P

    Vaillant 824 combi hot water

    Thanks , but I'm afraid its not moving any way. Tony
  8. P

    Vaillant 824 combi hot water

    Hi guys, the sensor nor the valve can not be fitted the wrong way. I can't see what you mean by the valve moving left & right. I would expect it to go up & down the shaft?
  9. P

    Vaillant 824 combi hot water

    Hi, Yes the holes are larger than on the original. I've tried a torch through the holes. It dosen't seem to do anything at all when calling for water?
  10. P

    Vaillant 824 combi hot water

    Hi guys, yes it was a genuine vaillant part. I don't know about the elongated ball. There didn't seem anything needing to engage. It was 2 compression joints to water pipes and a clip on to the secondary heat exchanger! ??
  11. P

    Vaillant 824 combi hot water

    Hi, Its the whole aqua sensor that I have replaced! I have tried cleaning the electrical contacts. I don't know if this helps to diagnose the problem but- if you put the boiler on warm start without the heating on then the rads get warm! Tony
  12. P

    Vaillant 824 combi hot water

    My heating is fine but on the hot water side when you open a tap the boiler does not fire. I have replaced the aqua sensor and now the diverter valve. Now I can get hot water if the boiler is set to warm start but it still does not fire if set to normal when a tap is opened. Any ideas?