Search results

  1. A

    Potterton Kingfisher MF Purge/Ignition Problem

    Many Thanks, I'll look into it. Ajed
  2. A

    Potterton Kingfisher MF Purge/Ignition Problem

    Ah-Ha tapping the pilot assembly gently produces 200v at the main gas valve and ignition. Guilt proven. Thankyou everyone. AJed
  3. A

    Potterton Kingfisher MF Purge/Ignition Problem

    Yep only 6V dc at the main gas valve, 200v at pilot. Could this be the flame sensor on the pilot faulty?
  4. A

    Potterton Kingfisher MF Purge/Ignition Problem

    Not yet, next time it occurs I'll put my DVM across it. Thanks. AJed
  5. A

    Potterton Kingfisher MF Purge/Ignition Problem

    Thanks for the reply, No more sparking occurs it just sits there with the pilot lit and the fan running for upto 2 hours before it lights the main burner apparently of its own accord. AJed
  6. A

    Potterton Kingfisher MF Purge/Ignition Problem

    I have a recently serviced Potterton Kingfisher MF CF80. the problem is the boiler sometimes does not ignite. The conditions are: room thermostat calling for heat, pump running, boiler begins to start up , fan runs, pilot light lit then it just stays there on the purge cycle with the fan...