Search results

  1. K

    BT landline problem

    think of it as renting exchange equipment and all jumpering in the exchange in theory should be in place as nearly everybody is converting/converted to BB so it is all at a touch of a button except if the jumper cable is not there. In most cases if you order a line from BT and you require BB...
  2. K

    BT landline problem

    in theory yes although you can have the dialtone on your line removed via software in the exchange however i would say that if it were software based then ring tone would not be present. if you imagine the likes of tiscali, tesco and all other braodband providers are now able to put there...
  3. K

    BT landline problem

    Have you rang BT because broadband signal is put on the line from a different part of the exchange from the line side. So you can have braodband without dialtone on the line. Here is what may have happened. In the exchange your line side has been disconnected thus no dialtone but you will get...
  4. K

    2core swa rear entry

    Thanks for your tips guys. I can never understand why they dont do clamps for the steel that you can use in certain cases and have the fly off the clamp a bit like copper pipe clamps. Surely it would be just as safe if they did. If life was easy it would be boring.
  5. K

    2core swa rear entry

    I cant remember the size but the plinth seems a good idea as it was a barn and they've had all this special insulation put in. looking in the back of my mind it seems to be a big ass cable for ther job.
  6. K

    2core swa rear entry

    Looks like i will have to hash the wall but as it has all been decorated and all the tradesmen have left Its gonna be a pain to put right. You can only work with what you got I suppose.
  7. K

    2core swa rear entry

    I know there is not alot of void behind to do it and it is tight up against an adjoining wall that doesnt help with the metal box with tails. The CU is metal clad and it just appears that it would be easier to use some form of clamp around the steel with a tail to the CU Im just concerned for...
  8. K

    Burglar alarm problem

    also but i will stand corrected if I must but I thought alarms should be either on a fused spur off the main or dedicated fused spur not off the lighting circuit but im probably wrong.
  9. K

    2core swa rear entry

    Right then heres one mr plasterboard man has boarded and plastered a wall and positioned all circuit cables including SWA feed to a new gym so that they come into the consumer unit from the rear. Any ideas on earthing the steel safley or do I tell the customer the best option is for bottom or...