Search results

  1. S

    Potterton Envoy - Refuses to Light

    Sorted - Ok - Here is what it was - On closer examination of the combustion chamber housing - I noticed what apeared to be a water stain running down the side towards the Hot surface ignighter connection -Mmmm Obviously not being able to get the boiler up and running I couldn't see what...
  2. S

    Potterton Envoy - Refuses to Light

    Well - I knew it was to good to be true- Insurance will only payout if boiler was serviced on a yearly basis - Its been 14 months since last one. Typical! So back to the drawing board - Baxi wont accept my money to come and fix it (Heatteam are too busy). What hope is there! It's times...
  3. S

    Potterton Envoy - Refuses to Light

    Your right it is a condensing boiler (Although it's not been doing much of anything at the moment) I have hade a look at this , and checked the pipe and the drain, although there was some water in the drain overflow outlet? (It is what the manual calls it) , nothing else found that looks out of...
  4. S

    Potterton Envoy - Refuses to Light

    Everything has been working fine - Gas supply is ok - My initial thought was the PCB which i think is about 170.00 , (a lot of money if it turns out to be something else) - The fact that it the whole fire up routine is exactly the same - even the final click (only without the spark) makes me...
  5. S

    Potterton Envoy - Refuses to Light

    For my sins I have a potterton Envoy 30 boiler - which has decided to stop working (Probably on the coldest day of the year to date). When I run on the HW or CH switch, the fan starts up and the boiler kicks into life like it normally would, however when it gets to the part where it is...
Back