  1. T

    Remeha 39c Combi ?

    great boilers,really quiet in operation. BUT needs to be on a very,very clean system,are you replacing a combi for a combi.?. i have a lot of respect for these dutch boilers,they need respect in fitting.
  2. T

    Confused about working pressure

    the 3 ring test is very out dated now,i think this was based on a main london gas cooker. saw a domestic range cooker yesterday and the 3 smallest burners will use double the amount of gas of the above cooker. if only a cooker installed its a good test but what about electric cookers.the 3...
  3. T

    Which one?

    for a combi to meet your needs other factors need to be considered. ie,mains water flow rate remember water companies can vary water flow rates at their discretion and existing showers.gas supply will probaly need to be re run from the gas meter in a large pipe. is your loft converted into a...
  4. T

    W.B DIVERTER 28 CDI

    can see your point but a more meatier o ring is difficiult to insert into plate heat exchanger and can distort the soft tube if forced and then a leak occors.
  5. T

    W.B DIVERTER 28 CDI

    no quick answer here sorry. but pay a LOTof attention to the hot water outlet tube you know its the one with no clamp or clip,relies on the SOFT copper tube being correctly inserted. it needs to be square with the female adpator on plate heat exch. change all o rings and washers. IMPORTANT...
  6. T

    Banging Honeywell V4073a mid position valve when HW demand

    simond you are very correct regarding honeywell 3 port valves and early worcester greenstar system boilers.worcester supplied an addendum,stating if an external 3 port valve is used it must not be a honeywell as the heating will stay on whilst no call for it. danfoss.drayton probaly have much...
  7. T

    Banging Honeywell V4073a mid position valve when HW demand

    i had same noise when valve moving between ports whilst pumping. honeywell valve will slam shut at times sending vibrations through out house pipes. something to do with pump over running,ie pump under independent control from boiler. had a suprima 60l on honeywell system. just exchanged the...
  8. T

    Shower advice

    keep the electric shower its a great back up when your combi boiler fails.
  9. T

    glowworm kfb 50

    thanks all,it was the fan running not running at full speed all the time. regards.
  10. T

    pcb repairs

    so are they selling dangerous equipment ?
  11. T

    pcb repairs

    adlink uk ltd nagi house alperton lane wembley ha0 1es 0208 991 5017 www.adlinkuk.com (site under review at this monent in time) they just a plumbers merchants and do boiler recon and new parts but very helpful people. i used them a lot when doing up houses in london. hope they are...
  12. T

    boiler breakdowns

    my opinion as a customer is that any person who does a repair on any thing. ie a car,a heating system,a television,an electrical installation etc has a duty of care to ensure all of the system is working safely as per makers instructions. for example a fully pumped heating system,with a back...
  13. T

    glowworm kfb 50

    thanks meldrew and andy. although the boiler is 10+ years old it is only used for heating in the winter months. the only parts in 10+ years are as above,if you can reccomend a new boiler which will be as reliable as this one let me know. my gas repair man is on holiday due to family...
  14. T

    glowworm kfb 50

    thanks for reply. pilot burner kit was also changed inc injector/electrode. pcb was changed due to not sparking. gas valve was changed as it was leaking gas internaly (letting by i think he said ) but this boiler starts up first time when inner case cover removed,maybe pulling more air into...
  15. T

    glowworm kfb 50

    just looking for some advice on my glowworm kfb 50.supplys heating only.10 year old approx. has been off during summer as we have seperate water heater. has been erattic operation all last week,it will only work with the inner case removed.i have asked my usual gas engineer to look at it but...