    noisy back boiler keeps me awake all night!!

    the noise is probably because the old boiler is scaled up and as it gets hot the scale exspands and becomes very noisey tell your neighbours to turn off the boiler overnight as it is the summer and they have probably left the hot water on 24 hours ,the cure is maybe another boiler but they can...
  2. F

    central heating boiler on all time

    this could be a faulty syncrone motor in your zone valve.
  3. F

    Britony water heaters

    they are all the same, good luck.
  4. F

    Ariston Euro Combi

    it could be that the tube off of the diverter is partially blocked the small tube on the left that goes to the little valve under the microswith or the diapragm in the small valve may be faulty, good luck.
  5. F

    Ariston Euro Combi

    this is probably the diverter valve right hand side at the rear, base, big brass valve, get a rgi to ex it as it can be tricky good luck.
  6. F

    ariston genus intermitant fault

    this is the PCB if you fire it up and look at the electrode through the window you may see it continue to spark as the rectifier in the board has gone its very common this boiler has a 2year ari warranty,good luck PS if you change the board you will see on the left hand side a row of pegs marked...
  7. F

    My pilot light will not stay on on my central heating system

    if you have a back boiler you will probably still get spares for it ,if not then you can exchange a back boiler for another back boiler under the new regs,good luck.call a corgi engineer.
  8. F

    Ariston Euro combi

    you should be able to get this at any good local parts stockist or online it will take about 1 hour to change and you have more than enough room around your boiler to exchange it.you will also need 2, 15mm fibre washers 2,22mm fibre washers 1,28mm fibre washer,i always remove the low pressure...
  9. F

    Marks out of 10

    as far as i know its not for sale anymore the last 1 i tryed to get about 18 months ago was sent down from scotland by PTS but was damaged when i got it so it went back,you have to have special conditions to fit non condensing boilers so i suppose they are now no longer available,but i must...
  10. F

    Marks out of 10

    1 OUT OF 10 .buy this if you want it to breakdown good luck
  11. F

    Gas Fire might be leaking gas PLEASE HELP

    PHONE 0800111999 NOW THERE IS NO CHARGE PHONE NOW THEY WILL COME OUT NOW SO DO IT NOW,good luck 0800111999 NOW
  12. F

    Ariston HE 24 error code E 34?

    rob is right but there can be 2 flue restrictors the other one you have to remove the fan and it is in the recouperator,also the fan should run at more than 0.9 mbar to make the aps work,ive changed so many aps,s ive lost count.good luck
  13. F

    Ariston Micro Genus 28HE Combi Boiler A01 Fault

    the problem is the recouperator and small pcb it takes about 1hour to fix if you get an ariston engineer in it is a bit tricky to change and you will need at least a 30mm gap to the right of the boiler to get it out,its a very common fault with this model blr,good luck.the small pcb is screwed...
  14. F

    Potterton Prima f60 problems

    this could also be the fan not running fast enough to open the aps or a faulty aps ,good luck
  15. F

    Low pressure in bathroom tap after drainning cold water tank

    you probably have an air lock,get a hose connect it to the cold mains probably kit sink cold tap and connect other end to bath cold open both taps for 10 seconds and that will probably do it,good luck.
  16. F

    combi boiler illegally installed?

    fan flued boilers should be at least 300 mm below an opening window or air vent.the condense coming out is mildly acidic and in time will mark your window.
  17. F

    Ariston Micro Genus 28HE Combi Boiler A01 Fault

    yes its very common when the warrantee runs out get insurance for it, :cry: as unfortunately they do let you down not the best boiler out there.
  18. F

    Ariston Micro Genus 28HE Combi Boiler A01 Fault

    yep its the pcb it will be done under warrantee call ariston
  19. F

    What are the Regs for putting a stove in please?

    its best if you call in a corgi engineer to inspect this 1st
  20. F

    prima 40 f boiler main burner repeatedly starts ans stops

    1st check the gas pressure you may have a faulty meter governor