Search results

  1. P

    Aga Range - Gas Aga Flue

    On a recent change of Gas Engineer my Aga was condemned as there seems to be a plate missing from the outside balanced flue. The engineer is not experienced with Agas and cannot go further with any advice or supply of parts. Can anyone recommend a Gas Aga engineer in the Huntingdon Cambs area...
  2. P

    Boiler Overheat

    I have a Myson Economist 60/80 S Plan system which has started to occasionally overheat shutting off the pilot light. Seems to occur only when pump stops when boiler is flaming at max output. Boiling/rumbling can be heard in the heat exchanger as there’s no pump-overrun and the overheat sensor...
  3. P

    Hoover Washing Machine HNL-7146 3 Flash Fault Code

    The machine does not fill with water when a wash is selected. It runs the pump to empty water and just cycles the drum back and forth. In diagnostic mode it shows error code 3 meaning:- Not drained in time allowed - washing machine fails to drain water Check that filter...
  4. P

    Gas boiler overheats on valve closure - vented system

    I need some ideas on diagnosis of an overheating boiler in a conventional vented central heating system. The system has two valves controlling heat circulation through radiators and a water cylinder respectively. When either of these two valves closes, without the other valve being open...
  5. P

    Extractor fan triggered by shower pump

    I'm looking for an extractor fan for bathroom/shower room. Ideally I'd like it to operate only when the shower pump operates with a timer to overun. Does anyone know of a product that will connect in this way? Thanks
  6. P

    Mira 88 shower control - Removal without damaging tiling

    Anyone tell me how to remove a Mira 88 please. I don't want to crack the surrounding tiles.
  7. P

    Please ignore - duplicated post

    Please ignore - duplicated post
  8. P

    Mira 88 - Fit service kit

    I have a Mira88 with a leak from the centre spindle. Based on experience with another property I went ahead and bought a service kit and new knobs. Trouble is this one hasn't been apart like the last one which was only a couple of years old. This one I can't rotate the big nutted cover...
  9. P

    What shall I do with this?

    Here's the proffesionally installed shower pump in my loft. :shock: What shall I do with it? I realised this weekend that the flow is restricted by the 2 flexi-hoses the plumbers put linking the 22mm pipes. The ID of the flexi hose has got to be less than 10mm? Thing is -...
  10. P

    New shower not draining

    I have a newly installed Bathstore Atlas shower which is not draining at the same rate as water goes in. Even if the trap in the shower tray is disassembled the water is still not drawn away. Water sits in the waste with the level going up an down as if there's an airlock. I am going to...
  11. P

    Advice on Radiator Positioning

    A radiator has been installed in my bathroom and I question its installation. It is a double radiator with fins 700mm x 600mm. Its been mounted just 2" off the floor - it means when you sit in the bath you can see the 4" skirting could not be fitted behind the rad - so you see a bit of bare...
  12. P

    Waterproofing a MDF bath panel

    Anyone got any ideas on how I waterproof the cut ends of mdf panelling? Had to remove the paneling from a newly "profesionally" installed bath to resecure the taps - water ingress into the mdf has occured already. Before I put the panels back I want to seal their end-grain (if you can call it...
  13. P

    Air in Heating System

    I can hear air bubbles in the pipework going to from the boiler. How do I rectify this? Air bubbles can also be heard travelling through the pump. The system is GF. A new pump was recently fitted (last 2 weeks). The system's been gravity flushed from drain points around the house till...
  14. P

    Supporting a C/H Circulation Pump

    My pump has failed today and I'm going to fit a replacement. The pump is currently unsupported by pipe clips suspended in the pipework which is unfixed apart from its connection to tank and heating pipework going away from the cupboard. There is a fair amount of noise coming from the pump...
  15. P

    16A Spur for Immersion Heater - Additional Fused Spurs

    I am thinking of making use of the 16A tripped supply in my airing cupboard for a shower pump. The only thing is a previous owner of the house has been there before me and taken two fused spurs off the back of the immersion fused outlet supplying the central heating boiler & circulation...
  16. P

    Shower Pump choice

    I know this subject appears frequently in the forums but I can't make a decision. I need a positive shower pump that is quiet - Choices are based on what is available online and from local suppliers Techflow CT45-2 Salamander CT-50 Monsoon Showermate 1.8 Can anyone advise which is...
Back