    MCB size and type required for a 10.8kW electric shower

    Hi Ban all Sheds, On closer inspection, it does appear to be 6mm cable as the earth is only single strand, so I will need to have the cable upgraded to 10mm. Luckily the cable is routed through plastic trunking, so it shouldn't be too big a job. Thanks Neil
  2. N

    MCB size and type required for a 10.8kW electric shower

    Hi Securespark Thanks for your reply. My consumer unit is rated at 100A. The unit is an old Square D unit, probably from late 80s if it is the origional fit in the house. The problem is that I think it is now obsolete, and I cannot seem to find a replacement MCB for it. The current...
  3. N

    MCB size and type required for a 10.8kW electric shower

    Hi Spark123 Thank you for your reply. The cable is 10mm which should be fine over a length of around 15 metres (in plastic ducting). For your interest, the circuit is also protected by a 30mA RCD within the consumer unit. Thanks Neil
  4. N

    MCB size and type required for a 10.8kW electric shower

    I've replaced an old electric shower with a 10.8 kW shower. However, I need to replace the current 30 Amp MCB with a higher rated MCB. The installation guide specifies 45 Amp. However, the nearest match to this I can get for my consumer unit is 40 Amp and 50 Amp. Should I...