  1. A

    Triton Electric Shower Buzz

    Its not the casing vibrating, and when its open the buzzing seems to be coming from the flow valve or heater cant really tell? It must be unrepairable then? But thanks everyone who replied
  2. A

    Triton Electric Shower Buzz

    I have a Triton Zante 2 9.5kw electric shower which after 2 or 3 minutes starts making quite a loud buzzing noise. It doesn't affect heating performance in anyway and temp stays consistent. In fact the loud buzz remains even if its run on the cold water setting. It's been doing it for maybe 6...
  3. A

    Replacing MR16 downlighters

    Box reads Suitable for use in Bathrooms Zone 1,2 and 3. Fire and Acoustic Rated Shower Downlight. Above the bathroom is large loftspace.
  4. A

    Replacing MR16 downlighters

    I have bought Bathroom rated GU10 mains voltage downlighters to replace the mr16 low voltage downlighters. Is replacing them as easy as this: 1:Remove current LV downlighter unit and transformer by disconnecting from junction box 2:Wire new Mains voltage downlighter unit directly to...
  5. A

    Replacing MR16 downlighters

    Thanks for clearing that up. The main reason I wanted to swop to mains voltage LED's was 1. To get rid of low voltage transformers (and having to replace them!) and 2. Don't want to replace the transformers with led drivers (which just seem as unreliable as transformers) 3. Long term goal is of...
  6. A

    Replacing MR16 downlighters

    I was thinking of changing the MR16 downlighters in the bathroom with GU10 mains voltage LED downlighters. Before I get an electrician I read on another site that this is against current building regs....is that right?
  7. A

    Elec Shower trips when OFF

    For anyone who searches and reads this post......the problem was a faulty MCB switch. Even the electrician who replaced it said its very rare, but that was the issue. Thanks for all the advice especially JohnW
  8. A

    Elec Shower trips when OFF

    I've now had a electrician do the relevant IR tests. He at first viewing the wiriing he said that he thought the fault would be that the wire was not the correct size....but after doing the tests he says the wire, although not giving the best results was doing the job and is not the issue...
  9. A

    Elec Shower trips when OFF

    I'm hoping JohnW is about, or someone who can help. In regards to this problem would the wiring being next to a central heating pipe be causing this issue?
  10. A

    Elec Shower trips when OFF

    I have visually checked the length of wiring as well now and can find no issues. Decided to change the isolator switch (again!) this time for a 50amp MK. If issue persists after this will call in an electrician (again!) to check and maybe change the MCB.
  11. A

    Elec Shower trips when OFF

    Yep....rcd trips when test button pressed
  12. A

    Elec Shower trips when OFF

    Hi Dave, Just to clarify: 1: Shower turned off at unit - then pull switch turned off = tripped by next time pull switch is turned on 2: Shower turned off at unit - pull switch left on = trips (sometimes 1 hour plus later, sometimes doesn't trip)
  13. A

    Elec Shower trips when OFF

    Power light on shower unit and neon switch are unlit
  14. A

    Elec Shower trips when OFF

    Yep John...thats the case. Turn shower off after use all OK...then sometime during the next 24 hours it will trip, and I have to go to cupboard to reset. For example after two showers Tuesday morning didn't trip at all. Two showers this morning all OK hadn't tripped during the half hour before...
  15. A

    Elec Shower trips when OFF

    Sorry John must of been editing my post to answer your question when you replied (see edit)
  16. A

    Elec Shower trips when OFF

    ****EDITED**** I can confirm that the shower is tripping during times when it is off.....sometimes hours after it been used. Not tripping when switched on and not tripping when switched off. Nobody is manually switching it off as it is in a locked cupboard outside which only I have access...
  17. A

    Elec Shower trips when OFF

    Just one last thought on this...... seeing as it seems to be tripping between the isolator switch (regardless of it being on or off) and the MCB could there be a problem with condensation with the MCB box being outside in a meter cupboard? It may just be coincidence but tripping events...
  18. A

    Elec Shower trips when OFF

    Is replacing the MCB a job for an electrician not recommended for Joe Public?
  19. A

    Elec Shower trips when OFF

    Hi Have now checked inside shower unit all very clean, wiring clean not oxidised and no sign off water leakage. Also the checked the three times changed switch, again clean/no heat damage. I really am baffled as two electricians have checked and said no issues but problem remains? Time...
  20. A

    Elec Shower trips when OFF

    The switch that trips is the one stickered "Shower Supply" Switch stickered "RCCB" stays ON