Search results

  1. G

    Daewoo Fridge freezer DRS30DSMB sn KE13XE26800331

    Daewoo Fridge freezer DRS30DSMB sn KE13XE26800331 looking for manual age of appliance and some test voltages to the compressor and overload device. Many thanks in advance . appliance not cooling and no sound coming from the compressor ,all lights and fans working ok .
  2. G

    Glen Dimplex Combi 30

    Hi I have a hw problem with a Glen Dimplex Combi 30 NG .When the hw is running and giving hw the ch light flickers then the hw light goes out and the ch light comes on,Then the ch light goes off and the hw light comes back on.This is causing hw fluctuating temperatures .My thought was the flow...
  3. G

    AQ6000 USER'S INSTRUCTIONS HERE

    Hi i have scanned them and now are in pdf may work better than the pictures i took i can email pdf but cant put pdf on the same site as the last link
  4. G

    Automatic Bypass Valve Setting For Smart Pump

    i found a wilo smart a pump on a vaillant ecopro 415 condensing open vented boiler ,boiler making kettling noise phoned vaillant and they said we dont recomend a smart pump on this boiler as it slows down to below the flow rate the boiler needs to function properly.so the smart pump maybe not so...
  5. G

    AQ6000 USER'S INSTRUCTIONS HERE

    AQ6000 USER'S INSTRUCTIONS HERE http://www.flickr.com/photos/burtskitecam/sets/72157629028521769/ WILL DO THEM IN PDF SOME TIME
  6. G

    leak detection fluid and restrictor elbows

    Hi i am looking to see if there was any advice on not using LDF on a restrictor elbow due to the fact that making the fibre washer wet with LDF can swell the washer and seal the leak ,antill the ldf drys out and the washer shrinks back and you have your gas leak back,thanks for any info on...
  7. G

    tricity bendix aw410w bearing replacment

    many thanks
  8. G

    tricity bendix aw410w bearing replacment

    hi i am looking to replace the bearings on a tricity bendix aw410w and wondered if there was a guide for doing this work, many thanks from burt
  9. G

    vaillant combi 824 rubber connection tube blocked

    //www.diynot.com/network/gasburt/albums/ This rubber tube is located on the return from the main heat exchanger it was nearly totaly filled with metal deposits (from a badly flushed system maybe) I was just wondering what caused the problem and why the muck built up at this place ,My...
  10. Untitled

    Untitled

  11. muck /vaillant tube

    muck /vaillant tube

    muck /vaillant tube
  12. G

    tight low roof space

    can i use foil board to do the low parts of the roof as the roof is only 1 meter at the center and timbers 2meters from the eves make it nearly impossible to get fiber glass into position would 50mm foil board give me good insulation many thanks from burt
  13. G

    Recommend a Wirefree Room Thermostat?

    hi first post here this forum is great full of info ,my problem is the drayton rf2 i just think its to complicated for general use the instructions don't seem to be very clear and most people end up using the plus minus buttons only ,so wasting functions that they or local authority have paid...
Back
Top