its a V4073a
just looked at the switchmaster 400 and it does have a terminal for hw off but no wires are left spare,
Right. Now we are getting somewhere.sorry, just checked sm400 again and it has heating off terminal, not water off
You do not have a gravity system! You have a kludged fully pumped system.This all depends on how easy it is to run a new cable from the Drayton and from the HW cylinder thermostat
i like the idea of the above
is it as easy as running 1 wire ??
would this mean i still have a GRAVITY SYSTEM ?
Until you sort the wiring out, you will have to leave the timer on G.currently i have the timer set @ G and its heating the water ok, should i change this to P even though the hw comes on with CH ?
That makes life complicated when it comes to altering the wiring.all wires were connected together etc by electrical blocks, there is no box so to speak ?
Until you sort the wiring out, you will have to leave the timer on G.currently i have the timer set @ G and its heating the water ok, should i change this to P even though the hw comes on with CH ?
That makes life complicated when it comes to altering the wiring.all wires were connected together etc by electrical blocks, there is no box so to speak ?
It would probably be best to buy a "wiring centre" (B&Q or plumbers merchant) and connect everything to that.
Here's the correct wiring diagram.
View media item 70
Terminal 2 is connected to Neutral but the thermostat switch only connects 1 and 3. The reason for the neutral connection is that the stat shown has an anticipator. This is a resistor between terminals 2 and 3 which warms up when the thermostat is calling for heat. The purpose of this is to reduce the difference between open and closed temperatures on bimetallic thermostats. Modern thermostats rely on solid state devices to measure temperature and do not need a neutral connection.
HI
Not sure if i read that right but the heating live output from the controller seems to be connected to the room stat as expected but terminal 2 of the roomstat appears to be connected to neutral so with the stat in position 2 would be a dead short ?
Or is that stat not actually a 2 way switch ?
Don't denigrate your own ability.that looks complicated and id be worried about messing it up ?
so what do i connect and where ?