Recent content by 680312

  1. 6

    single brick

    hi,ive had a wall knocked down and an rsj fitted.i'm wanting to extend the wall undetr the rsby 1 brick width and have fitted a steel channel from rsj to floor.I was going to tie it in with the existing wall by removing half a brick but the building inspector said to use a wall tie kit.Will it...
  2. 6

    gas pipe partially blocked?

    hopefully i'm not getting paranoid but what happens to the flux inside the gas pipe?have heard stories that it may corrode it over time
  3. 6

    gas pipe partially blocked?

    the guy came today and heated the pipe up and everything working fine,said it must have been flux.
  4. 6

    gas pipe partially blocked?

    the guy did seem to use a lot of flux as i had to clean it off.He also used solder fittings which he must have added quite abit extra as the pipe is coated with a good inch below fitting
  5. 6

    gas pipe partially blocked?

    had it altered by a gas safe plumber.He said,over the phone,that it would have a better supply than previously.He's coming out to take a look tomorrow
  6. 6

    gas pipe partially blocked?

    is it possible for a soldered joint to partially block a gas pipe reducing pressure?my cooker has a very limited gas pressure and will only give a very low flame.A t was taken from the boiler supply and now theres hardly any pressure.Boiler works fine
  7. 6

    new fence

    hi,i'm going to put up a new fence up soon and have ordered kpost(like postcrete) to fix the concrete posts in.i,m going fairly deep and will need at least 2 bags per post.Ive read you put the water in first and then mix but have also read if you add too much water it can weaken the mix.i'm just...
  8. 6

    bonding

    Havent got rcds only rewireable fuses.i know the gas meter goes to the earth terminal and the ring and lightining circuit but nothing else.
  9. 6

    bonding

    Ive noticed my boilers pipes are crossed bonded but when looking further the earth wire is cut and doesnt go anywhere.there is a fused switch to the boiler and was wondering if it was ok to to wire it to the earth in there as i cant get it back to the consumer unit without ripping the house apart
  10. 6

    bonding

    is it ok to earth bond pipework to a socket instead of running it back to a consumer unit?
  11. 6

    no completion certificate

    just rang corgi up who can give you a copy of your completion certificate and they say it was never registered!
  12. 6

    no completion certificate

    i never recieved a certificate and the plumber who installed it retired a bit back.am worried this will affect the house sale
  13. 6

    no completion certificate

    hi,i had my boiler installed in 2006 and dont seem to have a completion certificate.The thing is i've got my house up for sale and recieved a letter from the solicitors saying i need one and if i havent got one to obtain one from the relevant competent persons scheme listed on...
  14. 6

    air in boiler

    Is there anyway you can test the auto air vent is working on a combi? i can hear air in the boiler as it fires up to heat the water but disappears after a few seconds.i'm sure the the vent isnt removing the air
  15. 6

    air in boiler

    its an ideal isar.