Search results

  1. 6

    single brick

    hi,ive had a wall knocked down and an rsj fitted.i'm wanting to extend the wall undetr the rsby 1 brick width and have fitted a steel channel from rsj to floor.I was going to tie it in with the existing wall by removing half a brick but the building inspector said to use a wall tie kit.Will it...
  2. 6

    gas pipe partially blocked?

    hopefully i'm not getting paranoid but what happens to the flux inside the gas pipe?have heard stories that it may corrode it over time
  3. 6

    gas pipe partially blocked?

    the guy came today and heated the pipe up and everything working fine,said it must have been flux.
  4. 6

    gas pipe partially blocked?

    the guy did seem to use a lot of flux as i had to clean it off.He also used solder fittings which he must have added quite abit extra as the pipe is coated with a good inch below fitting
  5. 6

    gas pipe partially blocked?

    had it altered by a gas safe plumber.He said,over the phone,that it would have a better supply than previously.He's coming out to take a look tomorrow
  6. 6

    gas pipe partially blocked?

    is it possible for a soldered joint to partially block a gas pipe reducing pressure?my cooker has a very limited gas pressure and will only give a very low flame.A t was taken from the boiler supply and now theres hardly any pressure.Boiler works fine
  7. 6

    new fence

    hi,i'm going to put up a new fence up soon and have ordered kpost(like postcrete) to fix the concrete posts in.i,m going fairly deep and will need at least 2 bags per post.Ive read you put the water in first and then mix but have also read if you add too much water it can weaken the mix.i'm just...
  8. 6

    bonding

    Havent got rcds only rewireable fuses.i know the gas meter goes to the earth terminal and the ring and lightining circuit but nothing else.
  9. 6

    bonding

    Ive noticed my boilers pipes are crossed bonded but when looking further the earth wire is cut and doesnt go anywhere.there is a fused switch to the boiler and was wondering if it was ok to to wire it to the earth in there as i cant get it back to the consumer unit without ripping the house apart
  10. 6

    bonding

    is it ok to earth bond pipework to a socket instead of running it back to a consumer unit?
  11. 6

    no completion certificate

    just rang corgi up who can give you a copy of your completion certificate and they say it was never registered!
  12. 6

    no completion certificate

    i never recieved a certificate and the plumber who installed it retired a bit back.am worried this will affect the house sale
  13. 6

    no completion certificate

    hi,i had my boiler installed in 2006 and dont seem to have a completion certificate.The thing is i've got my house up for sale and recieved a letter from the solicitors saying i need one and if i havent got one to obtain one from the relevant competent persons scheme listed on...
  14. 6

    air in boiler

    Is there anyway you can test the auto air vent is working on a combi? i can hear air in the boiler as it fires up to heat the water but disappears after a few seconds.i'm sure the the vent isnt removing the air
  15. 6

    air in boiler

    its an ideal isar.
  16. 6

    air in boiler

    every time my boiler fires up i hear air in the boiler gushing round.after a few seconds the noise stops.ive bled the radiators which seem clear of air but am wondering if there's air in the boiler and the automatic air valve isnt working.i had a look at the valve and noticed that it didnt have...
  17. 6

    rsj

    I'm thinking of knocking a wall dividing a kitchen and toilet. The span of the room is 14ft by 8ft wide.The wall to be taken down is 7ft,halfway,along the 14ft span.The joists are 7x2 and rest on top of the wall dividing the kitchen.Im going to replace with an rsj as a precaution and am...
  18. 6

    supporting joists

    wasn't after anyone calculating a beam.There is no load bearing wall above and was thinking of doing it as a precaution as i'm not sure the joists at 7"x2"x14ft would be sufficient.
  19. 6

    supporting joists

    hi, i'm thinking about removing a wall in my kitchen but see the joists above rest on them.The joists go full length,14ft,but rest about 6ft along on a wall seperating two parts of my kitchen.The joists measure 7"x2" and the wall to be taken down is 8ft wide. Will i need to put up an rsj and if...
  20. 6

    ideal isar water temp drop

    ive noticed when i run the hot water for a while the temperature drops from 57c to 39c then the boiler fires back up reaching 57c again.it's a right pain when having a shower. Also on a couple of occasions there's been a different code in the idle position but reverts back to normal when...