My boy has a 6mx2mx2m outdoor concrete water tank that's probably 50 years old and there is slight leakage in a couple of spots on one outside wall. Drained the tank and there's some signs of the concrete deteriorating where the water is leaking. What's the best waterproofing product to use for...
Opening up the fireplace after removing the cast iron insert and find a rounded lump of extremely hard concrete in each of the back corners.
Suspect the insert wasn't original (house is 1906) due to the mortar and rubble that was behind it which came out very easily with an SDS.
Did these lumps...
My old style WC light pull has been tugged too often! The old switch/isolator seems to be a lighting circuit loop in and out with a pair of reds and a pair of blacks at the top and a single red and black off the load going to the ceiling rose (effectively 3 x T&E but actually 1 T&E, 2 single...
It's a SIAMP Trueflow cistern and a flavour of SIAMP fill valves, most likely a Compact 99B. Changing the whole valve has to be the last option due to access to the bottom of the cistern. Do these valves dis-assemble ?
After flushing the water the cistern continues to fill at full bore and chucks it down the overflow (middle of the flush valve) ... so must be an issue with the fill valve. When filling, the float lifts as the water comes in but doesn't shut off the water and the level rises above the float and...
As I understand the cat 5 DC pipe interrupters are intended for open outlet applications ie urinals, otherwise the water would discharge out of the vent holes. Are there any inline fittings that are suitable or do you have to go down the AUK1 air gap route.
The WRAS...
I've done the top half of the 1882 house in lime mortar (nhl3.5 and black sand) and now need to patch a few bits in the bottom half. Can't figure out what's been used as it's hard (like cement mortar) but has a creamy/pale surface but it's black underneath. Anyone got suggestions on how I get a...
I have an Alpha 200 Stratum ( Siemens) split load consumer unit with Siemens mcb's/RCCB from early 2000's. The 80A 30 RCCB 3SM3317-0 is burning when the 10Kw leccy shower is on. I've found an identical used replacement for the RCCB off fleabay 'cos I refuse to pay £250 for an equivalent...
My favourite 18/8 stainless pan almost parted company with it's handle yesterday when the top 2 of the 4 spot welds came away. Luckily I spotted it before attempting to carry the boiling pan of spuds to the sink. Can't get it spot welded locally but there seems to be some highly rated...
1882 property, original soil stack, top 3/4 is cast iron and pings when you tap it, lower 1/4 is unknown... grey finish and much duller sound when tapped. Anyone identify what it could be ?
6 years old, never touched as always fully open until the missus had a tweak and chucked out some black ( the o-ring perishing) and now weeps. There's no nut to tighten as it has a circlip so looks like a partial drain to sort it out. Anyone know what size o ring ? Retail is £39 a pair...