  1. K

    Ring main

    ok had an extension done put 10 new sockets in a ring. but only one feed coming from consumer box. is this ok or do i need to get a return to the consumer box? just to clarify, i have one main coming from consumer unit and going to the back of a socket and then a feed from the socket to...
  2. K

    Complete new house wiring with 2 showers

    What consumer unit would anyone recommend and is the wiring correct below Downstairs Ring Circuit B32 Downstairs Ring Circuit Kitchen B32 Upstairs Ring Circuit B32 Attic Ring Circuit B32 Downstairs Lighting B6 Upstairs Lighting B6 Attic Lighting B6 Cooker Cable 6mm Direct B32 (or...
  3. K

    House Wiring, With Shower

    What consumer unit would anyone recommend and is the wiring correct below Downstairs Ring Circuit B32 Downstairs Ring Circuit Kitchen B32 Upstairs Ring Circuit B32 Attic Ring Circuit B32 Downstairs...
  4. K

    Glow warm, Belgacom, 24c

    New boiler installed at a friends house. Been working fine for 3 month Now the hot water has stopped working, if you put the heating on sometimes the hot water becomes warm but within a second gets cold again. All mains, electrical OK, Radiators working fine too. what could it be? Its a...
  5. K

    Hoover Optima WHM 148 DF Dial Problem

    I have had a Hoover Optima WHM 148 DF for two years now and its been one of the worst machines ever. The current problem I have is the Dial not selecting the programme correctly. I select 30 ad it jumps from one programme to another. The programme it jumps to are close to the programmes that...
  6. K

    Vaillant 428 - no heating or hot water

    A new problem. Vaillant 428 installed on y plan. When hot water is on, the radiators were getting hot. so i thought this is cos the rad return feed is connected to the boiler return from hot water tank. So i thought i would install a one way valve on the radiator return. Now the water...
  7. K

    Vaillant 428 - Hot water no heating.

    Have the following installed. Vaillant 428 boiler Wireless Room Stat Y6630D1007 ST9400C Programmer L641 Cylinder stat V4073A 3 port motorized valve 10 Way junction box All honeywell Wired as follows
  8. K

    vaillant 428

    ok thanks for information in the past. now the boiler is fully functional but keeps going off and on. the temerature on the screen drops and it fires up again till it gets to about 80. pump is running all the time. When is goes off the central heating icon starts to flash. Any ideas.
  9. K

    Vaillant 428, SFH code

    Wired up the boiler, have this code SF.H flashing, and sometimes it comes on and sometimes it does not. Pump is also on. Nothing in manual. any ideas. Wiring is correct and checked again and again. Uusing the Honeywell y plan,
  10. K

    please HELP with Vaillant 428 on Y plan Honeywell System

    I had a new boiler installed by a gas fitter, Vaillant 428. He also installed 3 Way valve and a new Cylinder and a new pump and a room thermostat. All honeywell y plan pack. I'm an electrician and I thought I would wire it up according to the Y plan Wiring Diagram. But the problem is...