    CH Header tank position.

    Would it be acceptable to have the feed and vent pipes rising of the flow from the boiler, to keep header tank above it. While keeping the pump ~6m away in the airing cupboard. Or is this to far from the pump to be effective.
  2. D

    CH Header tank position.

    Just water pipes for bath room, kitchen etc(nothing that takes more than maines water presser). I presser test all that I can to 3bar (I have read that pressurized systems should be check to 10 bar. don't think I could pump that hard its bad enouth a 3) most my dry gadge will go to. I will /...
  3. D

    CH Header tank position.

    Would it be acceptable to have the feed and vent pipes rising of the flow from the boiler, to keep header tank above it. While keeping the pump ~6m away in the airing cupboard. Or is this to far from the pump to be effective. I'm not over keen on the thought of a sealed system. Just have...
  4. D

    CH Header tank position.

    Thanks Chris A bit of a rethink on the desinge is in order.
  5. D

    CH Header tank position.

    I have read in a few CH installation guides that the header tank should be positioned as close to vertical above the boiler as possible. Can you tell me what the reason for this is. As in our property the airing cupboard with the pump ext is ~6m run from were the boiler will be positioned and...
  6. D

    6Amp mcb tripping

    Thanks Most bulbs are the cheap supermarket home brand. Will try changing to a type C breaker. Dave
  7. D

    6Amp mcb tripping

    Having resonantly moved and changed an old fused CU to a new split load one. I am experiencing the mcb tripping on the current surge when a bulb blows. Is this standard behavure cased by faster tripping of the mcb compared to slow fuse blowing. At that the time of instalation there where no...
  8. D

    Fixing Rad Brackets

    I put blocks of wood in the wall attached to the Blocks then replasterd over. To give something firm to attach to as even with ancaring though the cavity to the blocks I found that I could not stop the wait of anything over about 2grams :-) from breaking the plaster board back into the cavity...
  9. D

    Chrome pipe

    What’s the best way to strip the chrome off plated copper pipe? As scraping it seems to leave the pipe surface rough. I'm concerned about the quality of the seal I will get on it. Thanks Dave
  10. D

    Compression fit joints

    Thanks I'll get some Jet Blue.
  11. D

    Compression fit joints

    I was always lead to belive it was good practise to prevent weeping around the olive. Dave
  12. D

    Compression fit joints

    Whats the best jointing compound to use on compression fit's. Is liquid PTFE as good as any or is one that dose not fully cure a safer option. Dave
  13. D

    Network 'CAT5' Cable

    You are totaly correct got my solids and stripes in the wrong order
  14. D

    Network 'CAT5' Cable

    CAT 5/6 standard is 1 Orange 2 Orange / White 3 Green 4 Blue / White 5 Blue 6 Green / White 7 Brown 8 Brown / White Make shore you only untwist just enough of the pairs to make the connections. Dave
  15. D

    Sizing Tanks

    Its all part of an extension so I'm building the cupboard around the tank. Part L I think I'm having to use more insulation than bricks and wood :-) Thanks again. Dave
  16. D

    Sizing Tanks

    Thanks corgiman. It will be providing the cold feeds for the power shower and baths as well. Is this still OK or do I need to go a bit bigger and is a 900x450 cylinder going to have the capacity to supply a 1.5bar pump. Thanks again for you assistance Dave
  17. D

    Sizing Tanks

    I am about to install a y plan vented central heating system and I need some help with choosing the correct size of the tanks. The usage will be 1 power shower 2 baths and 3 sinks. The sinks cold feed will come from the rising main the rest from the loft tank. It is unlikely that any of the...
  18. D

    Tarmac as hard core

    Thanks. We are i the initial process of building an extension and I have about 5 sql meters of the stuff to remove so it seemed a gould idear to reuse it as some of the hardcore base for the slab.
  19. D

    Strange problem with computer

    There are 4 different places that the problem could be. I nead some more info no exactly what hapens and in what order. I.E. Does the fan come on even for a second Any lights what exactly do to get it going again. As breezer said moden PC do not switch the mains voltage with the...
  20. D

    Tarmac as hard core

    Can chunks of tarmac be used as hard core for a concrete slab flore