  1. B

    Eurocell or Tricept profile?

    I've got comparable quote from 2 local companies for supply only PVCu , one is a small company that uses Eurocell profile and the other is a large company using Tricept Profile, both order them in rather than make them. Any advice on which is the better window? I'm inclined to go with the...
  2. B

    Alpha CB24 not firing problem help?

    We have a CB24 that broke down with a solid Red light fault, we could reset it, it would go through it's firing sequence but never fire up then the solid Red light comes on A. A local plumber took a look then ordered a new diverter valve, he fitted this but the problem remained, he then got a...
  3. B

    Alpha CB 24 solid red light solution idea's?

    Got a solid Red light on a CB24 , we have replaced the diverter valve , the flow switch and recently the overheat stat to solve a new problem of a solid Red light. Boiler tries to fire, spark is there, but it won't start. Have cleaned the system and heat exchanger and pump is working. Only thing...
  4. B

    Replacement for leaking Limefighter?

    Any help would be really appreciated I have a 2 year old Limefighter that has started leaking from a crack in the body, it must have got a knock, it's on the C inlet to a Gledhill Cylinder , I went to get a replacement but they have been superseded but after bit of reading they aren't really...
  5. B

    Configuring the Valiant VRC 470f?

    Got a new Ecotec plus system boiler and 470f weather compensator all in and working fine, even got the VR10 HTC HW stat working for full control but I think the remote isn't setup right, when the boiler is off during the day, the temp on the front panel says 22c when I know it's around 17c I can...
  6. B

    2 zones in small 3 bed worth it?

    I have a new Vailant System boiler with Gledhill indirect unvented tank, and we're deciding on the system controls, I think it's going to be easier to fit the VR65 & weather compensator VR470 than use the existing, but one thing came up. Vaillant are upgrading the VR65 to 66 this gives an extra...
  7. B

    New Valliant 624 system boiler and a US wifi thermostat?

    Thanks to the advice here I have a lovely new Valiant 624 system boiler with a Gledhill 180L indirect unvented cylinder, but I am undecided on what thermostat to run it on, my old system is ok but 18 years old so I have been looking at the new wifi programable thermostat's but they seem mostly...
  8. B

    New boiler and unvented cylinder?

    Am going to fit a new boiler and unvented indirect cylinder to replace an existing Gloworm Fuelsaver and Megaflow. The Megaflow is leaking from the cylinder itself and can only stop it with a recharge and as it's 18 years old it's nearing it's time to go anyway. So on advice from a mate I was...
  9. B

    Megaflow Cylinder leaking from the bottom help

    Jus returned from holiday to find out megaflow has leaked through to the kitchen, upon further inspection in must have been leaking for some time but we never noticed, a very slow drip, although all quite wet now, it's ruined the ceiling. It's not dripping from any pipes but around the foam at...
  10. B

    Window Cill repair

    This window Cill needs some looking at and I'm not sure how best to level it out, I have some new windows coming and would really like this to look perfectly flat. You can't really see from the pic but the further cill seems to slope back towards the window, I think the cill it self has split...
  11. B

    New UPVC sashes what's Best sealant to buy?

    I have some really nice UPVC sashes coming, whats the best sealant you can buy for the installation? Also as the old sash boxes will leave big gaps on the inside , what filler do you use? Eg foam filler Appreciate any advice I've never fitted them before. Alan
  12. B

    Boiler no longer working after power cut

    I have a Gloworm Fuelsave compleheat 55 The power cut happened last night and now this mornig the boiler won't fire up, there is no pump or fan and the ch low pressure warning light is on. I have tried the reset button, checked the fuse on PCB, I tried lowering the pressure then refilling...
  13. B

    Megaflow valve leaking?

    HI guys can anyone help I have a megaflow water tank, a slow leak has developed from a valve this is situated near the top of the tank. it seems to be a pressure relief valve made by RWC, it is in two parts the bottom being cast and joins to the flow and a discharge pipe but the top is a kinda...