  1. M

    Scantronic 9751en - cannot clear tamper/fault log

    I inherited the above system with 9930 key pad. I had to quickly move a pir sensir and the tamper alarm went off. My display now shows a couple of inactive tamper faults. I moved through the screens but I can't now set the alarm. The display mentions a rst code 7173. What do I need to do to...
  2. M

    why has my floor sunk?

    Hi, I had a double storey extension built over a year ago. The floor used for the 1st floor is 18mm or 25mm chipboard (ok, its cr@p), this is nailed to very large joists supported by an RSJ one side and hangers the other. This was all approved by the building regs inspector. The 1st floor...
  3. M

    Squeeky floor?? 18mm chipboard?!

    I had an extension built approx 1 year ago. My new bedroom conforms to the building regs (I have a certificate). The bedroom floor is 18mm tongue and groove chipboard I think. The trouble is that is squeeks and creaks really bad when walked on!!!! Any way to fix this?? Say perhaps large...
  4. M

    Pipes not long enough??

    Hi, Ive just taken my bathroom out, tiled the floor and put the tolilet, etc back. Unfortunately, the feed to the toilet is now too short (10mm) and one of the radiator connections is also too short (10mm). What are my options?? Is there a radiator valve that has increased hight to save...
  5. M

    Vent oven extractor onto neighbouring property?

    So we are getting a new kitchen fitted next week. We have a oven extractor which will vent the fumes outside. Trouble is outside will be onto my neighbours property!! Is that allowed? Many Thanks, Matt.
  6. M

    horizontal cable runs between sockets?

    Hi, I just want to check that horizontal cable runs between sockets on the ring is acceptable. I have seen other posts confirming this, but i just want to be sure given the new regs. I am extending my kitchen ring (then getting part p cert). Also, can somebody please confrim the latest...
  7. M

    45A choc block??

    Is it possibe eto get 45A choc block?? The biggest I can find is 30A!!! Help!! Thanks, Matt.
  8. M

    Extending the ring? Cabel too short!!!!

    I need to add another socket in my kitchen. I cannot spur off from an adjacent socket, as i need to add a spur off the new socket (fused outlet for fridge). Unfortunately, the existing cable doesnt reach the position of the new socket and there is no way i can replace the cable without...
  9. M

    Extension - Who issues the Part P certificate?

    Hi, I recently had an extension built. The builder arranged for the electrician. I have a certificate from the building inspector stating conformance to the building regs (he visited half a dozen times)....does this cover the electrics?? or does the electrics require its own Part P cert...
  10. M

    Oven Wiring - Can extend the cable?

    Hi, I need to move the oven switch 6" further away from the incloming feed (new bigger oven), the exisitng cable is not long enough! What are my options? The work I am doing will be certified and replacing the whole cable is NOT an option?? The oven is a dual fuel model, max rating at...