    RCD tripping

    Ian So you have really tested nothing, other than you no the RCD trips at 28mA. Would suggest you have not identified the problem and a bit more testing is required rather than "we will try this then try that" and hope the fault disappears?
  2. S

    earth loop impedance

    Hutchie Do you have an RCD fitted?
  3. S

    Certification in Scotland

    Rewiring a 2 bed end terrace house does not come into the certification scheme, providing it is not part of other works for which a building warrant was obtained and you therefor have no need to contact building control. You can carry out the works yourself, however this is not recommended...
  4. S

    Certification in Scotland

    What is the nature of the work you are proposing to carry out? The certification process comes into being mainly where a building warrant is required. Do a search on this forum
  5. S

    Live and neutral reversal

    Please don't misinterpret this question: I am not having a go... I am not Locking off the MCB would be a safe isolation proceedure, but does not eliminate a borrowed neutral situation. What would be safe isolation?
  6. S

    Picture of the week!™

    Appears I am not going to get an education today. My postings have been made in a light hearted mode with some knowledge. The picture show the cutters against a piece of 16mm and my assumption being that this is how they were damaged. This would have been the load current of the circuit...
  7. S

    Picture of the week!™

    "With a name like yours, you should really try to understand what happens during a short circuit " Im all ears awaiting your description
  8. S

    Fan Speed Control/Light Dimmer

    The fan installed will require to provide a number of air changes to meet with the building regulations. Im afraid fans are not tailor made for individual bathroom sizes and will run at the same speed all the time. Is this wind up time?
  9. S

    Picture of the week!™

    ricicle You a welder or what?
  10. S

    Picture of the week!™

    Must have been about 60A down the cable he cut?
  11. S

    testing question

    Bri You still using a crank-up megger?
  12. S

    Plastic Mounting Boxes - With or Without Earth Terminal?

    Is that 7/029 or 7/036 ???? and price in £sd please
  13. S

    testing question

    RF What you on tonight? "Why are there 2 RCDs in series? That is not good circuit design. " OSG Fig 3a ?????????????????????????????? Must admit Mark did not detail what the set up was
  14. S

    Immersion Wiring

    "It does not comply with regulation 530.3.2" Check the definition of Appliance and Systems No point in quoting regs if you dont understand them
  15. S

    Plastic Mounting Boxes - With or Without Earth Terminal?

    Mad Dr Its sounds like you want to partially flush a surface mounting back box. Rarely seen it done, but there are no reasons why not. You do not need to earth the plastic back box and if metal boxes are used, then, providing one lug is fixed, you do not need to earth it either
  16. S

    Immersion Wiring

    As the unit was made in Ireland, from Register of Eletrical Contractors of Ireland "Connecting Immersion Heaters Electrical Contractors are reminded of the need to check manufacturers instructions when connecting domestic dual immersion heaters incorporating a common thermostat for both...
  17. S

    Working in Scotland

    Its a bit yes and no. What should happen is that where works are part of a building warrant then they are required to be signed off by an Certifier of Construction working for an Approved Company, which can be a sole trader. The company and the CoC need to be registered with either SELECT or...
  18. S

    Wiring Diagram question needed answering

    Thanks Sparks Another case of manufactures wording to suit themselves, rather than fit a costly fuse in the fan
  19. S

    Wiring Diagram question needed answering

    Ali Why are you using 1 A double pole pull cord 2 A FCU All you need is a single pole pull cord and a fan isolator switch
  20. S

    Certification of new electric wiring

    If your extension is being done with a building warrant, before you start,by an COC, assuming your in Scotland.