That's what I was going to say.
240V on the orange = hws only.
240V on the white = mid position.
240V on the grey and White = HTG only. plus 240V output on the Orange wire.
240V on the grey = valve held in last position.
240V on the orange = hws only.
240V on the white = mid position.
240V on the grey and White = HTG only. plus 240V output on the Orange wire.
240V on the grey = valve held in last position.